Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 044K2104 Cty SM Rte 35 PM 13.1, 13.10 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Fred Booshehri |
Date Reported: |
07/27/2017 |
|
Address: |
TL Number: |
2 |
||
City: |
||||
Project Name: construct soldier pile wall |
||||
Prime Contractor: Golden State Bridge |
||||
Sample Taken Date: |
06/29/2017 |
Mix Design: |
na |
|
Contractor: Unknown |
Location: IN SAN MATEO COUNTY, ON ROUTE 35 AT POSTMILE 13.13, NEAR SKYLONDA, AT 0.1 MILE NORTH OF BEAR GULCH ROAD. |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.98 | 28.09 | 226617 | 8067.5 | 1 |
2 | 5.99 | 28.18 | 225821 | 8013.5 | 1 |
DIME Test ID: 2017-06-29-16-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 8040
Age of specimen: 14 days
Certified By: Mike Mullins
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 5.99 | 28.18 | 266781 | 9467.0 | 1 |
2 | 6.00 | 28.27 | 254984 | 9019.6 | 1 |
DIME Test ID: 2017-06-29-16-2
Number of specimens: 2
Compressive strength (to nearest 10 psi): 9240
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing