Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042G8904 Cty MRN Rte 1 PM 8.0 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Gina Choi |
Date Reported: |
07/03/2017 |
|
Address: |
TL Number: |
|
||
City: |
||||
Project Name: SOLDIER PILE WALL WITH TIEBACKS AND EMBANKMENT CONFINED SYSTEM. |
||||
Prime Contractor: THOMPSON BUILDERS CORPORATION |
||||
Sample Taken Date: |
06/05/2017 |
Mix Design: |
4201a |
|
Contractor: Unknown |
Location: MARIN COUNTY NEAR MUIR BEACH AT 2.1 MILES NORTH OF MUIR WOODS ROAD |
|||
Structure unique identifier: |
||||
Structure name: |
||||
Location of Pour: Soldier Pile Wall |
The following testing has been tested in accordance with:
ASTM C39-10 : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Cross sectional area of cylinder (in^2) | Average diameter of cylinder (in) | Compressive strength of cylinder (psi) | Maximum load on cylinder (lb) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 28.37 | 6.01 | 4743.5 | 134573 | 1 |
2 | 28.27 | 6.00 | 4868.3 | 137628 | 1 |
DIME Test ID: 2017-06-05-13-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 4810
Age of specimen: 28 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |