Print Report | Back to Sample Detail

Sample Record for 2017-05-23-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211777 DEA: 04209504 EFIS: 0412000116 QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN,SON-1-50.2/50.5,0.0/0.2
Work Description: REPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121
Location Description: MARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION COMPANY
Contractor Address: 2301 Kerner Blvd Ste. E, San Rafael, CA 94901
Resident Engineer: Scott Hislop Structure Rep.: Clifford Law

Sample Information

DIME Sample ID: 2017-05-23-2
TL Number from the TL Form: C741427
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 05/23/2017
Date that the sample was received by the laboratory/organization performing the testing: 05/24/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: A449 Bolt, Nut, Washer.
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: R D Fastener

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s): 369676A
Washer Mfg. Lot Number(s): 298421
Bolt Specification: A449
Bolt Length(s): 17.5
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 0.875
Bolt Mfg. Lot Number: 74281/1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 32

DIME Test ID: 2017-05-23-2-1
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Pitch Diameter 0.8064 in
Pitch Diameter 2nd no data in

Test 2 of 32

DIME Test ID: 2017-05-23-2-2
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Pitch Diameter 0.8085 in
Pitch Diameter 2nd no data in

Test 3 of 32

DIME Test ID: 2017-05-23-2-3
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Pitch Diameter 0.8078 in
Pitch Diameter 2nd no data in

Test 4 of 32

DIME Test ID: 2017-05-23-2-4
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Gage Type Pass

Test 5 of 32

DIME Test ID: 2017-05-23-2-5
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Gage Type Pass

Test 6 of 32

DIME Test ID: 2017-05-23-2-6
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Gage Type Pass

Test 7 of 32

DIME Test ID: 2017-05-23-2-7
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Measurement Average 4.24 mils

Test 8 of 32

DIME Test ID: 2017-05-23-2-8
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Measurement Average 3.72 mils

Test 9 of 32

DIME Test ID: 2017-05-23-2-9
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM F2329 - Hot Dip
Product Markings DR
Size 0.875 in
Bolt Length 17.5 in
Measurement Average 3.71 mils

Test 10 of 32

DIME Test ID: 2017-05-23-2-10
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Bolt Length no data in
Measurement Average 2.91 mils

Test 11 of 32

DIME Test ID: 2017-05-23-2-11
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Bolt Length no data in
Measurement Average 3.3 mils

Test 12 of 32

DIME Test ID: 2017-05-23-2-12
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM F2329 - Hot Dip
Product Markings DH N
Size 0.875 in
Bolt Length no data in
Measurement Average 3.25 mils

Test 13 of 32

DIME Test ID: 2017-05-23-2-13
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size .875 in
Bolt Length no data in
Measurement Average 2.61 mils

Test 14 of 32

DIME Test ID: 2017-05-23-2-14
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size .875 in
Bolt Length no data in
Measurement Average 2.65 mils

Test 15 of 32

DIME Test ID: 2017-05-23-2-15
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size .875 in
Bolt Length no data in
Measurement Average 3.19 mils

Test 16 of 32

DIME Test ID: 2017-05-23-2-16
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1AB9019177/8\"70717314.56Nut Proof LoadArnold
UTM 400KIP
Temperature 71 F

Test 17 of 32

DIME Test ID: 2017-05-23-2-17
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Nut Proof Load
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1BB9019177/8\"71211316.76Nut Proof LoadArnold
UTM 400KIP
Temperature 71 F

Test 18 of 32

DIME Test ID: 2017-05-23-2-18
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1AA449 7/8\" x 17.5\" Bolt 10 Deg Wedge0.4626612329414312313413061968
UTM 400KIP
Temperature 71

Test 19 of 32

DIME Test ID: 2017-05-23-2-19
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1BA449 7/8\" x 17.5\" Bolt 10 Deg Wedge0.4626750630014611713742663491
UTM 400KIP
Temperature 71

Test 20 of 32

DIME Test ID: 2017-05-23-2-20
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 0.875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 36.3
Spacing Ok

Test 21 of 32

DIME Test ID: 2017-05-23-2-21
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 0.875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 37.4
Spacing Ok

Test 22 of 32

DIME Test ID: 2017-05-23-2-22
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM F2329 - Hot Dip
Product Markings WS
Size 0.875 in
Bolt Length no data in
Hardness Reading Scale C Scale
Hardness Reading Average 36.25
Spacing Ok

Test 23 of 32

DIME Test ID: 2017-05-23-2-23
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Bolt Length 17.5 in
Pitch Diameter 08050 in
Pitch Diameter 2nd .8050 in

Test 24 of 32

DIME Test ID: 2017-05-23-2-24
Test Method: ASME B1.2-83r01: (Pitch Diameter) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Pitch Diameter)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Bolt Length 17.5 in
Pitch Diameter .8060 in
Pitch Diameter 2nd 0.8060 in

Test 25 of 32

DIME Test ID: 2017-05-23-2-25
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM A153 - Hot Dip
Product Markings D
Size .875 in
Bolt Length 17.5 in
Measurement Average 4.28 mils

Test 26 of 32

DIME Test ID: 2017-05-23-2-26
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 74281/1
Finish Coating ASTM A153 - Hot Dip
Product Markings D
Size .875 in
Bolt Length 17.5 in
Measurement Average 4.23 mils

Test 27 of 32

DIME Test ID: 2017-05-23-2-27
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Gage Type Pass

Test 28 of 32

DIME Test ID: 2017-05-23-2-28
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Gage Type Pass

Test 29 of 32

DIME Test ID: 2017-05-23-2-29
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Bolt Length no data in
Measurement Average 3.7 mils

Test 30 of 32

DIME Test ID: 2017-05-23-2-30
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 369676A
Finish Coating ASTM A153 - Hot Dip
Product Markings DH N
Size .875 in
Bolt Length no data in
Measurement Average 4.26 mils

Test 31 of 32

DIME Test ID: 2017-05-23-2-31
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1D
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM A153 - Hot Dip
Product Markings WS
Size .875 in
Bolt Length no data in
Measurement Average 3.62 mils

Test 32 of 32

DIME Test ID: 2017-05-23-2-32
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 05/26/2017
Date Tested: 05/25/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1E
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 298421
Finish Coating ASTM A153 - Hot Dip
Product Markings WS
Size .875 in
Bolt Length no data in
Measurement Average 2.48 mils

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To