Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 99999 DEA: 0322222
QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown
DIME Sample ID: 2025-01-01-13
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Redwood Valley Field Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Verification
Type of Material: Hot Mix Asphalt
Sample Taken Date: 01/01/2025
Date that the sample was received by the laboratory/organization performing the testing: 01/02/2025
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2" HMA-A 25% RAP PG 58-22
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Ukiah
DIME Test ID: 2025-01-01-13-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 01/28/2025
Date Tested: 01/03/2025
Submitted By Organization: CT D01 - Redwood Valley Field Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
4032.3 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5763.5 g
|
Mass of HMA Sample prior to ignition
|
1731.2 g
|
Corrected Asphalt Binder Content
|
5.72 %
|
Mass Loss
|
113.3 g
|
Mass of aggregate remaining after ignition
|
1617.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.82 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
no data0 %
|
Test Temperature
|
482 C
|