Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 66667 DEA: JMFPP EFIS: 0019000043
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for JMF Prequalification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-11-27-15
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 11/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 12/10/2024
The quantity of what the sample constitutes: 7 bags
A brief description of the sample: JMFPP Aggregates
From where was the sample collected: Source
Laboratory sample identification: 7002-JMF
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Otay
Source Identification (SMARA, name of Pit or Job Site): Not Provided
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plnat
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number: 220200 Otay Val
DIME Test ID: 2024-11-27-15-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What type of gradation is being tested?
|
Combined Gradation
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
98 %
|
Cumulative percent passing the 1/2 in. sieve
|
76 %
|
Cumulative percent passing the 3/8 in. sieve
|
61 %
|
Cumulative percent passing the #4 sieve
|
39 %
|
Cumulative percent passing the #8 sieve
|
32 %
|
Cumulative percent passing the #16 sieve
|
23 %
|
Cumulative percent passing the #30 sieve
|
15 %
|
Cumulative percent passing the #50 sieve
|
8 %
|
Cumulative percent passing the #100 sieve
|
4 %
|
Cumulative percent passing the #200 sieve
|
2.5 %
|
DIME Test ID: 2024-11-27-15-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method
|
1 - Combined Fracture Determination
|
Aggregate Size and Fracture Type
|
Coarse 2 Faced and Fine 1 Faced
|
Percentage of questionable, coarse, 2 faced particles tested
|
no data0 %
|
Percentage of questionable, fine, 1 faced particles tested
|
no data0 %
|
Percentage of fractured, coarse, 2 faced particles tested
|
99 %
|
Percentage of fractured, fine, 1 faced particles tested
|
100 %
|
DIME Test ID: 2024-11-27-15-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method
|
B
|
Determination
|
By Number
|
Dimensional ratio used
|
5:1
|
Weighted percentage of particles (by number) that were flat and elongated
|
0 %
|
Weighted percentage of particles (by number) that were not flat and elongated
|
0 %
|
DIME Test ID: 2024-11-27-15-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-11-27-15-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity
|
2.557
|
Bulk specific gravity (SSD Basis)
|
2.626
|
Apparent specific gravity
|
2.746
|
Absorption
|
2.7 %
|
DIME Test ID: 2024-11-27-15-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing
|
Bulk
|
Specific Gravity
|
2.670
|
Absorption
|
1.4 %
|
DIME Test ID: 2024-11-27-15-7
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation
|
B
|
Mass of sample on No.12 sieve (after 500 revolutions)
|
4365 grams
|
Percent loss after 100 revolutions
|
3 %
|
Percent loss after 500 revolutions
|
13 %
|
DIME Test ID: 2024-11-27-15-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed?
|
Method A
|
Bulk dry specific gravity
|
2.557
|
Average uncompacted voids
|
43.3 %
|
DIME Test ID: 2024-11-27-15-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test: RAP Rice
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
US Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7475.6 grams
|
Mass of oven-dry sample in air for Sample 1
|
1557.5 grams
|
Mass of container filled with the sample and water for Sample 1
|
8409.8 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.499
|
Theoretical maximum density at 25°C (77°F)
|
155.6 lb/ft^3
|
DIME Test ID: 2024-11-27-15-10
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used?
|
Yes
|
Aggregate correction factor for the 2 in. sieve (% passing)
|
0.0 %
|
Aggregate correction factor for the 1 1/2 in. sieve (% passing)
|
0.0 %
|
Aggregate correction factor for the 1 in. sieve (% passing)
|
0.0 %
|
Aggregate correction factor for the 3/4 in. sieve (% passing)
|
0.0 %
|
Aggregate correction factor for the 1/2 in. sieve (% passing)
|
0.0 %
|
Aggregate correction factor for the 3/8 in. sieve (% passing)
|
-0.4 %
|
Aggregate correction factor for the #4 sieve (% passing)
|
-2.4 %
|
Aggregate correction factor for the #8 sieve (% passing)
|
-1.0 %
|
Aggregate correction factor for the #16 sieve (% passing)
|
-1.7 %
|
Aggregate correction factor for the #30 sieve (% passing)
|
-2.3 %
|
Aggregate correction factor for the #50 sieve (% passing)
|
-2.0 %
|
Aggregate correction factor for the #100 sieve (% passing)
|
-1.7 %
|
Aggregate correction factor for the #200 sieve (% passing)
|
-1.6 %
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
100 %
|
Cumulative percent passing the 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 3/8 in. sieve
|
99 %
|
Cumulative percent passing the #4 sieve
|
86 %
|
Cumulative percent passing the #8 sieve
|
75 %
|
Cumulative percent passing the #16 sieve
|
59 %
|
Cumulative percent passing the #30 sieve
|
43 %
|
Cumulative percent passing the #50 sieve
|
27 %
|
Cumulative percent passing the #100 sieve
|
16 %
|
Cumulative percent passing the #200 sieve
|
10.4 %
|
DIME Test ID: 2024-11-27-15-11
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Is an aggregate correction factor used?
|
No
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
Cumulative percent passing the 1/2 in. sieve
|
82 %
|
Cumulative percent passing the 3/8 in. sieve
|
73 %
|
Cumulative percent passing the #4 sieve
|
59 %
|
Cumulative percent passing the #8 sieve
|
43 %
|
Cumulative percent passing the #16 sieve
|
33 %
|
Cumulative percent passing the #30 sieve
|
23 %
|
Cumulative percent passing the #50 sieve
|
14 %
|
Cumulative percent passing the #100 sieve
|
9 %
|
Cumulative percent passing the #200 sieve
|
6.0 %
|
DIME Test ID: 2024-11-27-15-12
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 01/16/2025
Date Tested: 01/16/2025
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 518-8709
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: