Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994976 DEA: 060X3304 EFIS: 0618000055
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-5-R0.0/4.4
Work Description: REPLACE ROADWAY PAVEMENT WITH HMA AND CONCRETE.
Location Description: KERN COUNTY AT AND NEAR LEBEC FROM LOS ANGELES COUNTY LINE TO GRAPEVINE CREEK
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: Unknown
Resident Engineer: Joy Denny Structure Rep.: Travis Landas
DIME Sample ID: 2024-11-01-69
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 11/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 11/02/2024
The quantity of what the sample constitutes: 1200-1500CY
A brief description of the sample: JPCP- cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SPCI onsite
The concrete mix design number: G3-18-PCC-128R
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 128
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-11-01-69-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 12/13/2024
Date Tested: 12/13/2024
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test: initial cure temperature not comply with test method
Test Result Compliance: does not comply
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.01 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.63 in^2
|
Compressive strength (to nearest 10 psi)
|
6110 psi
|
Maximum load on cylinder 1
|
76950 lb
|
Maximum load on cylinder 2
|
74620 lb
|
Maximum load on cylinder 3
|
79100 lb
|
Compressive strength of cylinder 1
|
6,121.7 psi
|
Type of fracture pattern of cylinder 1
|
2
|
Compressive strength of cylinder 2
|
5,936.4 psi
|
Compressive strength of cylinder 3
|
6,262.9 psi
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
42 days
|
Age of specimen in hours
|
no data0 hours
|