Sample Record for 2017-04-11-6
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 210735 DEA: 071193U4 EFIS: 0713000007
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-37.2/42.4
Work Description: CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS.
Location Description: IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA
Contractor Name: Guy F. Atkinson
Contractor Address: 18201 Von Karman Ave, Suite #800, IRVINE CA 92612
Resident Engineer: Rodolfo Cao Structure Rep.: David Win
Sample Information
DIME Sample ID: 2017-04-11-6
TL Number from the TL Form: C943830
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 04/11/2017
Date that the sample was received by the laboratory/organization performing the testing: 04/14/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: A615 Grade 75 Threaded Bar
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Gerdau
Material Information
Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: #11
Nut Specification for Threaded Bar: ASTM A897
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 6214302903
Nut Heat Number(s): H296
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown
Test Results
Test 1 of 2
DIME Test ID: 2017-04-11-6-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/14/2017
Date Tested: 04/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 1 | #11 A615 | L67-075-17 | 1.56 | 124490 | 84490 | 16 | A615 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
2000KIP
|
Test 2 of 2
DIME Test ID: 2017-04-11-6-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 04/14/2017
Date Tested: 04/14/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Threaded Bar and Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By | 2 | #11 A615 | L67-075-17 | 1.56 | 123460 | 83530 | 0 | A615 Threaded Bar and Nut | Brian |
| |
Temperature
|
72 F
|
UTM
|
2000KIP
|