Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-04-07-6
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 04/07/2017
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2017
The quantity of what the sample constitutes: 3
A brief description of the sample: F1554 anchor rods
From where was the sample collected: Manufacturer
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Universal Industrial Sales

Material Information

Rocap Number(s):
Heat Number(s): PL16108449
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: F1554-Gr55
Bolt Length(s): 5'-2"
Nut Specification: NA
Washer Specification: NA
Finish: HDG/Plain
Diameter/Size: 2-1/2"
Bolt Mfg. Lot Number:
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 4

DIME Test ID: 2017-04-07-6-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 04/12/2017
Date Tested: 04/12/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 2
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
PL161084590.4960.1932615858570027.6Brian
PL161084590.4950.1924612748593025.7Brian
UTM 67KIP
Temperature 72 F

Test 2 of 4

DIME Test ID: 2017-04-07-6-2
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/17/2017
Date Tested: 04/17/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) PL16108459
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings YELLOW PAINT
Size 2.5 in
Bolt Length 60 in
Measurement Average 6.75 mils

Test 3 of 4

DIME Test ID: 2017-04-07-6-3
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/17/2017
Date Tested: 04/17/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) PL16108459
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings YELLOW PAINT
Size 2.5 in
Bolt Length 60 in
Measurement Average 5.77 mils

Test 4 of 4

DIME Test ID: 2017-04-07-6-4
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 04/17/2017
Date Tested: 04/17/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1C
Rocap Number no data
Heat Number(s) PL16108459
Mfg. Lot Number no data
Finish Coating ASTM A153 - Hot Dip
Product Markings YELLOW PAINT
Size 2.5 in
Bolt Length 60 in
Measurement Average 5.69 mils