Print Report | Back to Sample Detail

Sample Record for 2017-04-01-2

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 210695 DEA: 080K2924 EFIS: 0812000099 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-32.9/R37.4
Work Description: REPLACE EXISTING (PCCP) WITH (RSCP).
Location Description: IN/NEAR REDLANDS FROM 0.2 MILE W/O FORD STREET TO 0.4 MILE E/O LIVEOAK CANYON ROAD.
Contractor Name: J. MCLOUGHLIN ENGINEERING CO., INC.
Contractor Address: 10641 Fulton Court, Rancho Cucamonga, CA 91730
Resident Engineer: Maged Youssef Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-04-01-2
TL Number from the TL Form: 20-2
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 04/01/2017
Date that the sample was received by the laboratory/organization performing the testing: 04/03/2017
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12 LCB
From where was the sample collected: Job Site
Laboratory sample identification: 945-20-2
Structure unique identifier: 10WB STA 733 10 to 697 00
Structure name: Unknown
The fabricator/manufacturer/facility name: CTS SHORT LOAD RAPID SET

Material Information

The concrete mix design number: CTS-30-RAM
The truck number from where the sample was collected: Unknown
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: NP
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2017-04-01-2-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 04/11/2017
Date Tested: 04/08/2017
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 6
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.03 in
Average diameter of cylinder 2 6.02 in
Average diameter of cylinder 3 6.02 in
Average diameter of cylinder 4 6.01 in
Average diameter of cylinder 5 6.00 in
Average diameter of cylinder 6 6.02 in
Cross sectional area of cylinder 1 28.56 in^2
Cross sectional area of cylinder 2 28.46 in^2
Cross sectional area of cylinder 3 28.46 in^2
Cross sectional area of cylinder 4 28.37 in^2
Cross sectional area of cylinder 5 28.27 in^2
Cross sectional area of cylinder 6 28.46 in^2
Compressive strength (to nearest 10 psi) 2600 psi
Maximum load on cylinder 1 76170 lb
Maximum load on cylinder 2 74610 lb
Maximum load on cylinder 3 71770 lb
Maximum load on cylinder 4 72610 lb
Maximum load on cylinder 5 75750 lb
Maximum load on cylinder 6 72240 lb
Compressive strength of cylinder 1 2667.0 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 2621.6 psi
Compressive strength of cylinder 3 2521.8 psi
Compressive strength of cylinder 4 2559.4 psi
Compressive strength of cylinder 5 2679.5 psi
Compressive strength of cylinder 6 2538.3 psi
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 2
Type of fracture pattern of cylinder 4 1
Type of fracture pattern of cylinder 5 2
Type of fracture pattern of cylinder 6 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Correction factor for cylinder 3 no data
Correction factor for cylinder 4 no data
Correction factor for cylinder 5 no data
Correction factor for cylinder 6 no data
Age of specimen 7 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.