Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 3825 DEA: 07138204 EFIS: 0700000142
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-47,103-3.5/4.6,0.0/1.1
Work Description: REPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location Description: LOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Contractor Name: M C M CONSTRUCTION INC
Contractor Address: P O BOX 620, NORTH HIGHLANDS, CA 95660
Resident Engineer: Daniel Leon Structure Rep.: Andy Chen
DIME Sample ID: 2017-03-21-4
TL Number from the TL Form: 191875-B
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 03/21/2017
Date that the sample was received by the laboratory/organization performing the testing: 03/27/2017
The quantity of what the sample constitutes: 6
A brief description of the sample: 6x12
From where was the sample collected: Job Site
Laboratory sample identification: 816-75B
Structure unique identifier: SCHUYLER HEIM BRIDGE
Structure name: CIDH PILE 21A
The fabricator/manufacturer/facility name: CATALINA PACIFIC
The concrete mix design number: CIDH720ER6
The truck number from where the sample was collected: 4933
The batch plant ticket number from where the sample was collected: 978511
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: CHUTE
Where the material sample would have been placed if not sampled: Unknown
From Lot No.: Unknown
Bag Lot No.: Unknown
DIME Test ID: 2017-03-21-4-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/02/2017
Date Tested: 05/02/2017
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617/CTM521
|
Average diameter of cylinder 1
|
5.98 in
|
Average diameter of cylinder 2
|
5.99 in
|
Cross sectional area of cylinder 1
|
28.09 in^2
|
Cross sectional area of cylinder 2
|
28.18 in^2
|
Compressive strength (to nearest 10 psi)
|
8910 psi
|
Maximum load on cylinder 1
|
250210 lb
|
Maximum load on cylinder 2
|
251310 lb
|
Compressive strength of cylinder 1
|
8907.4 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
8918.0 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
no data
|
Age of specimen
|
42 days
|
Age of specimen in hours
|
no data
|