Print Report | Back to Sample Detail

Sample Record for 2017-02-23-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-02-23-8
TL Number from the TL Form: C939311
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Threaded Bar
Sample Taken Date: 02/23/2017
Date that the sample was received by the laboratory/organization performing the testing: 02/28/2017
The quantity of what the sample constitutes: 2
A brief description of the sample: A615 Grade 75 Threaded Bar
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSI Gerdau

Material Information

Production or Authorization Testing: Production Testing
Threaded Bar Specification: ASTM A615
Threaded Bar Grade: 75
Threaded Bar Type: Deformed
Rebar Size: 10
Nut Specification for Threaded Bar: A536
System Manufacturer: DSI
Epoxy Coating Color: NA
Threaded Bar Application: Threaded Bar
Coating Standards: Uncoated
Bar Heat Number(s): 6214211502
Nut Heat Number(s): E166
Bar Lot Number: Unknown
Nut Lot Number: Unknown
Coupler Heat Number(s): Unknown
Coupler Grade: Unknown

Test Results

Test 1 of 2

DIME Test ID: 2017-02-23-8-1
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/06/2017
Date Tested: 03/06/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1#10 Bar Heat #6214211502, Nut Heat E166#L08017171.271142237824816.3A615 Bar & NutFred
Temperature 72 F
UTM 400KIP

Test 2 of 2

DIME Test ID: 2017-02-23-8-2
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 03/06/2017
Date Tested: 03/06/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A615 Bar & Nut
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
2#10 Bar Heat #6214211502, Nut Heat E166#L08017171.27113928781160A615 Bar & NutFred
Temperature 72 F
UTM 400KIP