Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-710-6.0-9.4
Work Description: Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location Description: Port of Long Beach (District 7)
Contractor Name: Shimmick/FCC/Impregilo (SFI) JV
Contractor Address: 11 Golden Shore, Suite 330, Long Beach, CA 90802
Resident Engineer: Structure Rep.: Sami Deeb
DIME Sample ID: 2017-02-09-7
TL Number from the TL Form: C952665
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Steel Check Sample Plate
Sample Taken Date: 02/09/2017
Date that the sample was received by the laboratory/organization performing the testing: 02/17/2017
The quantity of what the sample constitutes: 1
A brief description of the sample: A709 Steel Check Sample
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stinger Bridge Iron
Heat Number(s): 812s42220
Material Specification: A709
Grade: HPS 50W
Thickness: 3.125
Shape: Square
Metal Foundry Manufacturer (Mill): Steel Girder
Plate Dimension: 12 x 12
DIME Test ID: 2017-02-09-7-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/01/2017
Date Tested: 02/24/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
2
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | | 812S42220 | 0.493 | 0.1909 | 54792 | 78030 | 29.8 | Fred | | 812S42220 | 0.491 | 0.1893 | 53948 | 78560 | 32.5 | Fred |
| |
UTM
|
67KIP
|
Temperature
|
72 F
|
DIME Test ID: 2017-02-09-7-2
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Verified Date: 03/01/2017
Date Tested: 02/27/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature Required
|
10 oF
|
Minimum Energy Required
|
30 ftlb
|
Test Temperature 1
|
10.1 oF
|
Impact Energy 1
|
274 ftlb
|
Impact Energy 2
|
291 ftlb
|
Impact Energy 3
|
291 ftlb
|
Average Impact Energy
|
285 ftlb
|
Striker Radius
|
8 mm
|
Value Exceeds The Machine Capacity?
|
No
|
DIME Test ID: 2017-02-09-7-3
Test Method: SMTL CHEM-16: Steel Chemistry Analysis
Verified Date: 03/01/2017
Date Tested: 02/27/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: