Sample Record for 2024-07-18-123
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
Sample Information
DIME Sample ID: 2024-07-18-123
TL Number from the TL Form:
Sample Submitted By Organization: Pavement Engineers
Sample Organization Contact: (530) 913-3751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 07/18/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/19/2024
The quantity of what the sample constitutes: 63CY
A brief description of the sample: shotcrete
From where was the sample collected: Job Site
Laboratory sample identification: L242443
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Northgate Ready Mix
Material Information
The concrete mix design number: B753BF15
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: back of truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2024-07-18-123-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/26/2024
Date Tested: 08/15/2024
Submitted By Organization: Pavement Engineers
Organization Address: 3650 Industrial Boulevard,
Organization City: West Sacramento
Organization State: CA
Organization Zipcode: 95691
Organization Email: michelleh@pavementengineering.com
Organization Phone: (530) 913-3751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
Average diameter of cylinder 1
|
2.93 in
|
Average diameter of cylinder 2
|
2.93 in
|
Average diameter of cylinder 3
|
2.93 in
|
Cross sectional area of cylinder 1
|
6.74 in^2
|
Cross sectional area of cylinder 2
|
6.74 in^2
|
Cross sectional area of cylinder 3
|
6.74 in^2
|
Compressive strength (to nearest 10 psi)
|
4000 psi
|
Maximum load on cylinder 1
|
27900 lb
|
Maximum load on cylinder 2
|
26961 lb
|
Maximum load on cylinder 3
|
25950 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
4
|
Type of fracture pattern of cylinder 3
|
4
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|
Serial number of delivery ticket, if available
|
no data
|