Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 100X7524 Cty AMA Rte 49 PM 0.0/30.9 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Pawan Garg |
Date Reported: |
09/27/2024 |
|
Address: |
TL Number: |
206465 |
||
City: |
||||
Project Name: Bridge widening and upgrading rails |
||||
Prime Contractor: BRIDGEWAY CIVIL CONSTRUCTORS INC. |
||||
Sample Taken Date: |
09/20/2024 |
Mix Design: |
Unknown |
|
Contractor: Unknown |
Location : On State Highway in Amador and Calaveras Counties at Mokelumne River Bridge |
|||
Structure unique identifier: |
||||
Structure name: Abutment 5 |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 42455 | 3362.0 | 1 |
2 | 4.02 | 12.69 | 45093 | 3553.0 | 1 |
3 | 4.01 | 12.63 | 46229 | 3660 | 1 |
DIME Test ID: 2024-09-20-33-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3530
Age of specimen: 7 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
![]() |
TL- Report of Laboratory Testing