Print Report | Back to Sample Detail

Sample Record for 2017-01-26-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211434 DEA: 120N3604 EFIS: 1214000004 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-91-R1.0,5.4
Work Description: OVERLAY OGAC,RETAINING WALL,CONC BARRIER,LIGHTING,SIGNALS,ADA IMPROVE
Location Description: ORANGE COUNTY IN BUENA PARK AND ANAHEIM AT VALLEY VIEW STREET OVERCROSSING AND AT STATE COLLEGE BOULEVARD UNDERCROSSING
Contractor Name: ODONNELL CONSTRUCTION, INC.
Contractor Address: 599 W. Covina Boulevard, San Dimas, CA 91773-2911
Resident Engineer: Mohamad Yacoub Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2017-01-26-11
TL Number from the TL Form: C953656
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Welded Hoops
Sample Taken Date: 01/26/2017
Date that the sample was received by the laboratory/organization performing the testing: 01/30/2017
The quantity of what the sample constitutes: 4
A brief description of the sample: Flash Welded Rebar Hoops
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: TNT Rebar

Material Information

Production or Authorization Testing: Authorization Testing
Service or Ultimate: Service
Rebar Heat Number(s): 4049973
Hoop Manufacturer Lot Number(s): 1
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Size: 4
Diameter of Hoop: 2'-2"
Epoxy Coated: No
Epoxy Coating Color: NA
Rebar Manufacturer: TNT
Welding Company: TNT Rebar
Coating Standards: Uncoated
Weld Type: Flash Welded

Test Results

Test 1 of 4

DIME Test ID: 2017-01-26-11-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/31/2017
Date Tested: 01/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke in Heat Affected Area
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11#4/13mm0.21646082300Bar Broke in Heat Affected AreaBrian
UTM 400KIP
Temperature 72 F

Test 2 of 4

DIME Test ID: 2017-01-26-11-2
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/31/2017
Date Tested: 01/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke in Heat Affected Area
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
21#4/13mm0.21794089700Bar Broke in Heat Affected AreaBrian
UTM 400KIP
Temperature 72 F

Test 3 of 4

DIME Test ID: 2017-01-26-11-3
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/31/2017
Date Tested: 01/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
31#4/13mm0.21807090350Bar BrokeBrian
UTM 400KIP
Temperature 72 F

Test 4 of 4

DIME Test ID: 2017-01-26-11-5
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 01/31/2017
Date Tested: 01/31/2017
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Bar Broke; OK Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
41#4/13mm0.21820091000Bar BrokeBrian
UTM 400KIP
Temperature 72 F