Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994785 DEA: 023H32U4 EFIS: 0221000164
QA Service Level: 1
DIST-CO-RTE-PM: 02-SIS-I5-2.5/R15.9
Work Description: Roadway rehabilitation and bridge improvements along I5 in Mount Shasta
Location Description: SIS I5 2.5/R15.9
Contractor Name: Gordon Stout - Walsh/Myers
Contractor Address: 1390 Willow Pass Rd Suite 950, Concord, CA 94520
Resident Engineer: Austin Henry Structure Rep.: Mike Sears
DIME Sample ID: 2024-07-08-105
TL Number from the TL Form: 972010
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/08/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/08/2024
The quantity of what the sample constitutes: 16 Boxes
A brief description of the sample: 1/2" HMA-A w/25% RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D79633
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc. - Northstate Asphalt (Redding CA)
DIME Test ID: 2024-07-08-105-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 07/12/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.504
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7333 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1508.3 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8239 grams
|
|
Temperature of Water
|
24 °F
|
|
Specific Gravity for Sample 1
|
2.504
|
|
Theoretical maximum density at 25°C (77°F)
|
2496.7 kg/m^3
|
DIME Test ID: 2024-07-08-105-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 07/17/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.422
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.425
|
|
Bulk Specific Gravity 2
|
2.423
|
|
Bulk Specific Gravity 3
|
2.417
|
|
Average Bulk Specific Gravity
|
2.422
|
DIME Test ID: 2024-07-08-105-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/09/2024
Date Tested: 07/17/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=3.3%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
3.2 %
|
|
Percent Air Voids 2
|
3.2 %
|
|
Percent Air Voids 3
|
3.5 %
|
|
Average Percent Air Voids
|
3.3 %
|
DIME Test ID: 2024-07-08-105-4
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/09/2024
Date Tested: 07/25/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=122 psi, S2=119 psi, TSR=98%
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
122 psi
|
|
Average Wet Tensile Strength
|
119 psi
|
|
Tensile Strength Ratio
|
0.98
|
DIME Test ID: 2024-07-08-105-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/09/2024
Date Tested: 07/15/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: pb=5.40%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3111.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4714.8 g
|
|
Mass of HMA Sample prior to ignition
|
1602.9 g
|
|
Corrected Asphalt Binder Content
|
5.4 %
|
|
Mass Loss
|
101.6 g
|
|
Mass of aggregate remaining after ignition
|
1501.3 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.75 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.19 %
|
|
Test Temperature
|
538 C
|