Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215003 DEA: 040J6204 EFIS: 0414000019
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-680-12.4/21.9
Work Description: REHABILITATE PAVEMENT - RPL APP/DEP SLABS, 14 BRIDGES
Location Description: ALAMEDA COUNTY AT SUNOL AND IN PLEASANTON AND DUBLIN FROM KOOPMANN ROAD UNDERCROSSING TO ALAMEDA COUNTY LINE
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 Townsgate Road, Suite 200, Westlake Village, CA 91361
Resident Engineer: Eddie Dike Structure Rep.: Betty Geng
DIME Sample ID: 2024-09-04-44
TL Number from the TL Form: C772194
Sample Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Sample Organization Contact: (510) 224-6127
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 09/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1/2"RHMA-G
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Pleasanton
DIME Test ID: 2024-09-04-44-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 09/05/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Cores 12B, 12C, 13A, 13B
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7335.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
1524.2 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8220.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.385
|
|
Theoretical maximum density at 25°C (77°F)
|
2378 kg/m^3
|
DIME Test ID: 2024-09-04-44-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 09/06/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Cores 12B,12C, 14A
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.203
|
|
Bulk Specific Gravity 2
|
2.181
|
|
Bulk Specific Gravity 3
|
2.165
|
|
Average Bulk Specific Gravity
|
2.183
|
DIME Test ID: 2024-09-04-44-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/09/2024
Date Tested: 09/06/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Cores 12B, 12C, 13A
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
7.6 %
|
|
Percent Air Voids 2
|
8.6 %
|
|
Percent Air Voids 3
|
9.2 %
|
|
Average Percent Air Voids
|
8.5 %
|
DIME Test ID: 2024-09-04-44-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 09/06/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Core 13B
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.188
|
DIME Test ID: 2024-09-04-44-5
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/09/2024
Date Tested: 09/06/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Core 13B
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-09-04-44-6
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/10/2024
Date Tested: 09/10/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Burn #1
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2896 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4413.3 g
|
|
Mass of HMA Sample prior to ignition
|
1517.3 g
|
|
Corrected Asphalt Binder Content
|
7.3 %
|
|
Mass Loss
|
122.2 g
|
|
Mass of aggregate remaining after ignition
|
1395.1 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.55 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
482 C
|
DIME Test ID: 2024-09-04-44-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/10/2024
Date Tested: 09/10/2024
Submitted By Organization: CT D04 - Pleasanton Field Laboratory
Organization Address: 5675 B Gibratar Drive,
Organization City: Pleasanton
Organization State: CA
Organization Zipcode: 94588
Organization Email: dennis.yeung@dot.ca.gov
Organization Phone: (510) 224-6127
General Comments for this Test: Burn #2
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
2864.5 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
4400.9 g
|
|
Mass of HMA Sample prior to ignition
|
1536.4 g
|
|
Corrected Asphalt Binder Content
|
7.83 %
|
|
Mass Loss
|
131.8 g
|
|
Mass of aggregate remaining after ignition
|
1404.6 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.55 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.2 %
|
|
Test Temperature
|
482 C
|