Print Report | Back to Sample Detail

Sample Record for 2024-09-01-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000284 DEA: 041Y5004 EFIS: 0422000498 QA Service Level: 1
DIST-CO-RTE-PM: 04-SF-280-R2.7/R4.2L
Work Description: PLACE POLYESTER CONCRETE OVERLAY, AND REPLACE JOINT SEAL.
Location Description: THE CITY AND COUNTY OF SAN FRANCISCO AT VARIOUS LOCATIONS FROM MONTEREY BOULEVARD ON-RAMP OVERCROSSING TO ROUTE 280/101 SEPARATION
Contractor Name: MCCUEN CONSTRUCTION, INC.
Contractor Address: 1537 Canal Road, Sparks, NV 89434
Resident Engineer: Marcus Washington Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-09-01-1
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 09/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/04/2024
The quantity of what the sample constitutes: 2 tankers
A brief description of the sample: 1 gallon can / PPC 1121 RESIN
From where was the sample collected: Source
Laboratory sample identification: 000119KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia

Material Information

Mfg. Lot Number(s): AZ4H01333
Batch number: AZ4H01333
Mix number: AZ4H01333

Test Results

Test 1 of 6

DIME Test ID: 2024-09-01-1-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 09/23/2024
Date Tested: 09/13/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Viscosity 101.5

Test 2 of 6

DIME Test ID: 2024-09-01-1-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 09/23/2024
Date Tested: 09/13/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units pounds/gallons
Liquid Density (pounds per gallon) 9

Test 3 of 6

DIME Test ID: 2024-09-01-1-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 09/23/2024
Date Tested: 09/23/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested 6
Conditioning procedure 18/25/50+5/70
Speed of testing 0.45 in/min
Sample 1 Width 0.485 in
Sample 1 Ultimate strength 2904 psi
Sample 1 Thickness 0.261 in
Sample 1 Area 0.1266 in^2
Sample 1 Ultimate Strength Actual 367.646 lbs
Sample 1 percent elongation 63.3 %
Sample 1 Time no data0 MM:SS
Sample 2 Width 0.485 in
Sample 2 Thickness 0.262 in
Sample 2 Area 0.1271 in^2
Sample 2 Ultimate strength 2911 psi
Sample 2 Ultimate Strength Actual 369.988 lbs
Sample 2 percent elongation 60 %
Sample 2 Time no data0 MM:SS
Sample 3 Width 0.486 in
Sample 3 Thickness 0.264 in
Sample 3 Area 0.1283 in^2
Sample 3 Ultimate strength 3122 psi
Sample 3 Ultimate Strength Actual 400.553 lbs
Sample 3 percent elongation 71.1 %
Sample 3 Time no data0 MM:SS
Sample 4 Width 0.486 in
Sample 4 Thickness 0.261 in
Sample 4 Area 0.1268 in^2
Sample 4 Ultimate strength 23328.1 psi
Sample 4 Ultimate Strength Actual 2958 lbs
Sample 4 percent elongation 58.6 %
Sample 4 Time no data0 MM:SS
Sample 5 Width 0.487 in
Sample 5 Thickness 0.256 in
Sample 5 Area 0.1247 in^2
Sample 5 Ultimate strength 2950 psi
Sample 5 Ultimate Strength Actual 367.865 lbs
Sample 5 percent elongation 52.3 %
Sample 5 Time no data0 MM:SS
Sample 6 Width 0.484 in
Sample 6 Thickness 0.261 in
Sample 6 Area 0.1263 in^2
Sample 6 Ultimate strength 2963 psi
Sample 6 Ultimate Strength Actual 374.227 lbs
Sample 6 percent elongation 61 %
Sample 6 Time no data0 MM:SS
Ultimate Strength Average 6363 psi
Percent Elongation Average 61 %

Test 4 of 6

DIME Test ID: 2024-09-01-1-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 09/23/2024
Date Tested: 09/13/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination 46.13

Test 5 of 6

DIME Test ID: 2024-09-01-1-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 09/23/2024
Date Tested: 09/06/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1 24hr
Maximum applied load (P) for Sample 1 1162.21 lb
Span length for Sample 1 9 in
Break location for Sample 1 bond
Specimen defects/notes for Sample 1 no data
Surface type for Sample 1 SSD
Modulus of rupture (R) for Sample 1 581.106 psi
Curing history for Sample 2 24hr
Maximum applied load (P) for Sample 2 1094.07 lb
Span length for Sample 2 9 in
Break location for Sample 2 bond
Specimen defects/notes for Sample 2 no data
Surface type for Sample 2 SSD
Modulus of rupture (R) for Sample 2 547.037 psi
Curing history for Sample 3 24hr
Maximum applied load (P) for Sample 3 1077.27 lb
Span length for Sample 3 9 in
Break location for Sample 3 bond
Specimen defects/notes for Sample 3 no data
Surface type for Sample 3 SSD
Modulus of rupture (R) for Sample 3 538.633 psi

Test 6 of 6

DIME Test ID: 2024-09-01-1-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 09/23/2024
Date Tested: 09/09/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid 153.9 mm
Room Temperature 78 f
Tare weight no data
Initial weight 100.057 grams
Weight at 5 minutes 99.996 grams
Weight at 10 minutes 99.933 grams
Weight at 15 minutes 99.869 grams
Weight at 20 minutes 99.804 grams
Weight at 25 minutes 99.74 grams
Weight at 30 minutes 99.665 grams
Final weight 99.67 grams
Total weight loss 0.39 grams
Calculated radius of gallon can lid in cm 7.695 cm
Lid Factor 53.757 m^2
Volatile emission 20.804 grams/m^2