Print Report | Back to Sample Detail

Sample Record for 2024-09-05-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993318 DEA: 11423704 EFIS: 1116000059 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-8-R31.8/R41.7
Work Description: PLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location Description: SAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real, Ste 200, Carlsbad, CA 92008
Resident Engineer: Art Pannu Structure Rep.: Carlos Guzman

Sample Information

DIME Sample ID: 2024-09-05-1
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Retest
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 09/05/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/05/2024
The quantity of what the sample constitutes: 505 each
A brief description of the sample: Epoxy Coated Dowel Bars
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier: 57-0688R
Structure name: Sweetwater River Bridge
The fabricator/manufacturer/facility name: American Highway

Material Information

Dowel Metal Heat Number: 1202062387
Dowel Epoxy Batch Number: CH2613TV CH0684UP
Dowel Coating Specification: ASTM A934
Dowel Size: 1.5 in
Dowel Coating Color: Purple
Dowel Manufacturer: Nucor
Dowel Coater: American Highway Simplex
Release Number:
Quality Assurance Code:
Rebar Size (#): 1-1/2" x 18"

Test Results

Test

DIME Test ID: 2024-09-05-1-1
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 09/12/2024
Date Tested: 09/11/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
First Bar Mean 7.81
Second Bar Mean 8.61
Lower spec. limit LSL 7 mils
Upper spec. limit USL 40 mils
Total mean value 8.21
Total number of values less than LSL no data
Total number of values greater than USL no data

Test

DIME Test ID: 2024-09-05-1-2
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 09/12/2024
Date Tested: 09/11/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: brian.ellis@dot.ca.gov
Organization Phone: (916) 380-8623
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
Total Number of Holiday 4
Total Length 3 ft
Holidays Per Linear Foot of Bar 1.3 holiday per ft
Holiday Test Pass/Fail Fail