Print Report | Back to Sample Detail

Sample Record for 2024-08-28-56

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995085 DEA: 07322904 EFIS: 0716000059 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-27-0.0/18.6
Work Description: REMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: 28548 Livingston Ave, Valencia, CA 91355
Resident Engineer: Ravin Maru Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-28-56
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 08/28/2024
Date that the sample was received by the laboratory/organization performing the testing: 09/04/2024
The quantity of what the sample constitutes: 4 Bags of Comb. Agg, 1 Can each of Scrap & Hi-Nat
A brief description of the sample: JMF 1/2" RHMA-G-SP 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0450G-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan -Sun Valley

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-19-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Belt cut at Vulcan-Sun Valley
Where the material sample would have been placed if not sampled: Asphalt Paving
Primary Aggregate Nominal Size: 1/2 inch
The concrete mix design number: 326120M SVA VLO
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-08-28-56-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-4AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-5AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-7AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory
2024-08-28-56-8ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)09/05/2024Not scheduledSatish JainCT D08 - Fontana Southern Regional Laboratory