Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995051 DEA: 023H6804 EFIS: 0218000006
QA Service Level: 1
DIST-CO-RTE-PM: 02-SHA-5-R28.8/R44.1
Work Description: PLACE RHMA, PAINT TRAFFIC STRIPE, & INSTALL FIBER OPTIC CABLE SYSTEM.
Location Description: SHASTA COUNTY ABOUT 6 MILES NORTH OF SHASTA LAKE CITY FROM PIT RIVER BRIDGE TO 1.2 MILES SOUTH OF DOG CREEK BRIDGE
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 17400 CLEAR CREEK ROAD, REDDING, CA 96001
Resident Engineer: Kyle Higgins Structure Rep.: Unknown
DIME Sample ID: 2024-08-12-79
TL Number from the TL Form: 851378
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/13/2024
The quantity of what the sample constitutes: 16 boxes of 3/4" Type A HMA with RAP
A brief description of the sample: 3/4" Type A HMA with 23.6% RAP
From where was the sample collected: Manufacturer
Laboratory sample identification: D79688
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: J F Shea Construction Inc - Fawndale Rock and Asphalt - Redding CA
DIME Test ID: 2024-08-12-79-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/04/2024
Date Tested: 08/13/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.587
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
SI Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7332.3 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2578.4 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8914 grams
|
|
Temperature of Water
|
24 °F
|
|
Specific Gravity for Sample 1
|
2.587
|
|
Theoretical maximum density at 25°C (77°F)
|
2579.5 kg/m^3
|
DIME Test ID: 2024-08-12-79-2
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/04/2024
Date Tested: 09/04/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.469
Test Result Compliance: not applicable
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.468
|
|
Bulk Specific Gravity 2
|
2.465
|
|
Bulk Specific Gravity 3
|
2.475
|
|
Average Bulk Specific Gravity
|
2.469
|
DIME Test ID: 2024-08-12-79-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/04/2024
Date Tested: 09/04/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=4.5%
Test Result Compliance: complies
Additional Comments When Verified:
|
Percent Air Voids
|
4.6 %
|
|
Percent Air Voids 2
|
4.7 %
|
|
Percent Air Voids 3
|
4.3 %
|
|
Average Percent Air Voids
|
4.5 %
|
DIME Test ID: 2024-08-12-79-4
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/04/2024
Date Tested: 08/22/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=133, S2=127, TSR=95%
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
133 psi
|
|
Average Wet Tensile Strength
|
127 psi
|
|
Tensile Strength Ratio
|
0.95
|
DIME Test ID: 2024-08-12-79-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/03/2024
Date Tested: 10/01/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pr=4.96%
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
3112.8 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5212.2 g
|
|
Mass of HMA Sample prior to ignition
|
2099.4 g
|
|
Corrected Asphalt Binder Content
|
4.97 %
|
|
Mass Loss
|
117.9 g
|
|
Mass of aggregate remaining after ignition
|
1981.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.51 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.14 %
|
|
Test Temperature
|
538 C
|