Sample Record for 2024-06-04-132
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993333 DEA: 04264724 EFIS: 0419000068
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN-101-R20.8/27.1
Work Description: CIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location Description: MARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
Contractor Name: GHILOTTI CONSTRUCTION CO. INC. (RILEY GENAZZI & JOSH SERAFINO)
Contractor Address: 246 GHILOTTI AVE., SANTA ROSA, CA 95407
Resident Engineer: Fabio La Serna Structure Rep.: Jeremy Light
Sample Information
DIME Sample ID: 2024-06-04-132
TL Number from the TL Form:
Sample Submitted By Organization: Pavement Engineers
Sample Organization Contact: (530) 913-3751
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/04/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/05/2024
The quantity of what the sample constitutes: 40cy
A brief description of the sample: concrete aggregate
From where was the sample collected: Supplier
Laboratory sample identification: S-176 to -181
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Shamrock Materials Petaluma
Material Information
The concrete mix design number: SL-4201CG
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 619112
Concrete batch plant:
The fabricator/manufacturer designation for the sample: SL-4201CG
A detailed description of where the material sample was collected: plant
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 2
DIME Test ID: 2024-06-04-132-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/04/2024
Date Tested: 06/11/2024
Submitted By Organization: Pavement Engineers
Organization Address: 3650 Industrial Boulevard,
Organization City: West Sacramento
Organization State: CA
Organization Zipcode: 95691
Organization Email: michelleh@pavementengineering.com
Organization Phone: (530) 913-3751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5600 psi
|
Maximum load on cylinder 1
|
71680 lb
|
Maximum load on cylinder 2
|
68785 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|
Serial number of delivery ticket, if available
|
619112
|
Test 2 of 2
DIME Test ID: 2024-06-04-132-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/04/2024
Date Tested: 07/02/2024
Submitted By Organization: Pavement Engineers
Organization Address: 3650 Industrial Boulevard,
Organization City: West Sacramento
Organization State: CA
Organization Zipcode: 95691
Organization Email: michelleh@pavementengineering.com
Organization Phone: (530) 913-3751
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Apparent mass of submerged cylinder 1
|
no data0 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
7150 psi
|
Maximum load on cylinder 1
|
88920 lb
|
Maximum load on cylinder 2
|
88540 lb
|
Maximum load on cylinder 3
|
92260 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|
Serial number of delivery ticket, if available
|
619112
|