Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994368 DEA: 040K7804 EFIS: 0416000138
QA Service Level: 1
DIST-CO-RTE-PM: 04-SM-84-21.5/25.7
Work Description: REPLACE AC SURFACING, UPGRADE CURB RAMPS, REPLACE MBGR WITH MGS.
Location Description: SAN MATEO COUNTY IN WOODSIDE AND REDWOOD CITY ON ROUTE 84 FROM ROUTE 280 TO ROUTE 101
Contractor Name: GHILOTTI BROS., INC.
Contractor Address: 525 Jacoby Street, San Rafael, CA 94901
Resident Engineer: Mohamed Fouad Structure Rep.: Unknown
DIME Sample ID: 2024-08-28-51
TL Number from the TL Form:
Sample Submitted By Organization: CT D04 - Hayward Field Laboratory
Sample Organization Contact: (510) 723-0168
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/28/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/29/2024
The quantity of what the sample constitutes: 0-750 Tons
A brief description of the sample: 3/4-Imch RHMA-G
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DSG Sunol Plant
DIME Test ID: 2024-08-28-51-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/03/2024
Date Tested: 08/01/2024
Submitted By Organization: CT D04 - Hayward Field Laboratory
Organization Address: 21339 Cabot Boulevard,
Organization City: Hayward
Organization State: CA
Organization Zipcode: 94545
Organization Email: pamela.brown@dot.ca.gov
Organization Phone: (510) 385-8258
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
2070.9 g
|
|
Corrected Asphalt Binder Content
|
7.29 %
|
|
Mass Loss
|
164.5 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.55 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
0.11 %
|
|
Test Temperature
|
482 C
|