Unit system used?
|
US Units
|
Number of specimens
|
6
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
5.95 in
|
Average diameter of cylinder 2
|
5.95 in
|
Average diameter of cylinder 3
|
5.95 in
|
Average diameter of cylinder 4
|
5.95 in
|
Average diameter of cylinder 5
|
5.95 in
|
Average diameter of cylinder 6
|
5.95 in
|
Cross sectional area of cylinder 1
|
27.81 in^2
|
Cross sectional area of cylinder 2
|
27.81 in^2
|
Cross sectional area of cylinder 3
|
27.81 in^2
|
Cross sectional area of cylinder 4
|
27.81 in^2
|
Cross sectional area of cylinder 5
|
27.81 in^2
|
Cross sectional area of cylinder 6
|
27.81 in^2
|
Compressive strength (to nearest 10 psi)
|
4280 psi
|
Maximum load on cylinder 1
|
118890 lb
|
Maximum load on cylinder 2
|
124003 lb
|
Maximum load on cylinder 3
|
116891 lb
|
Maximum load on cylinder 4
|
117869 lb
|
Maximum load on cylinder 5
|
114115 lb
|
Maximum load on cylinder 6
|
121844 lb
|
Compressive strength of cylinder 1
|
4275.1 psi
|
Type of fracture pattern of cylinder 1
|
3
|
Compressive strength of cylinder 2
|
4458.9 psi
|
Compressive strength of cylinder 3
|
4203.2 psi
|
Compressive strength of cylinder 4
|
4238.4 psi
|
Compressive strength of cylinder 5
|
4103.4 psi
|
Compressive strength of cylinder 6
|
4381.3 psi
|
Type of fracture pattern of cylinder 2
|
3
|
Type of fracture pattern of cylinder 3
|
3
|
Type of fracture pattern of cylinder 4
|
3
|
Type of fracture pattern of cylinder 5
|
3
|
Type of fracture pattern of cylinder 6
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Correction factor for cylinder 4
|
1
|
Correction factor for cylinder 5
|
1
|
Correction factor for cylinder 6
|
1
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
no data0 hours
|