Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 031H9904 Cty PLA Rte 80 PM 68.3/69.7,0.0/R2.7 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Randie Babbini |
Date Reported: |
10/08/2024 |
|
|
Address: |
TL Number: |
084205 |
||
|
City: |
||||
|
Project Name: RDWY EXC, PLACE HMA & JPCP, SLAB REPLACEMENT & POLYESTER CONC OVERLAY. |
||||
|
Prime Contractor: A. TEICHERT & SON INC DBA TEICHERT CONSTRUCTION |
||||
|
Sample Taken Date: |
08/27/2024 |
Mix Design: |
Unknown |
|
|
Contractor: Unknown |
Location : PLACER AND NEVADA COUNTIES NEAR KINGVALE FROM 0.3 MILE WEST OF TROY UNDERCROSSING TO 0.2 MILE EAST OF SODA SPRINGS OVERCROSSING |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.01 | 12.63 | 65083 | 5153.0 | 1 |
| 2 | 4.01 | 12.63 | 61107 | 4839.0 | 1 |
| 3 | 4.00 | 12.57 | 63412 | 5046 | 1 |
DIME Test ID: 2024-08-27-38-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5010
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.00 | 12.57 | 79265 | 6308.0 | 1 |
| 2 | 4.00 | 12.57 | 79959 | 6363.0 | 1 |
| 3 | 4.00 | 12.57 | 76702 | 6104 | 1 |
DIME Test ID: 2024-08-27-38-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6260
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 3.99 | 12.5 | 80967 | 6476.0 | 1 |
| 2 | 4.00 | 12.57 | 81960 | 6522.0 | 1 |
| 3 | 3.99 | 12.5 | 83417 | 6671 | 1 |
DIME Test ID: 2024-08-27-38-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 6560
Age of specimen: 42 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing