REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
Randie Babbini |
Date Reported: |
10/08/2024 |
|
|
Address: |
TL Number: |
084204 |
||
|
City: |
||||
|
Project Name: RDWY EXC, PLACE HMA & JPCP, SLAB REPLACEMENT & POLYESTER CONC OVERLAY. |
||||
|
Prime Contractor: A. TEICHERT & SON INC DBA TEICHERT CONSTRUCTION |
||||
|
Sample Taken Date: |
08/27/2024 |
Mix Design: |
Unknown |
|
|
Contractor: Unknown |
Location : PLACER AND NEVADA COUNTIES NEAR KINGVALE FROM 0.3 MILE WEST OF TROY UNDERCROSSING TO 0.2 MILE EAST OF SODA SPRINGS OVERCROSSING |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.01 | 12.63 | 55404 | 4387.0 | 1 |
| 2 | 4.01 | 12.63 | 55216 | 4372.0 | 1 |
| 3 | 4.00 | 12.57 | 55384 | 4407 | 1 |
DIME Test ID: 2024-08-27-37-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4390
Age of specimen: 7 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.01 | 12.63 | 67301 | 5329.0 | 1 |
| 2 | 4.01 | 12.63 | 68292 | 5407.0 | 1 |
| 3 | 4.00 | 12.57 | 66498 | 5292 | 1 |
DIME Test ID: 2024-08-27-37-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5340
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.00 | 12.57 | 69868 | 5560.0 | 1 |
| 2 | 4.01 | 12.63 | 72572 | 5746.0 | 1 |
| 3 | 4.01 | 12.63 | 72779 | 5763 | 1 |
DIME Test ID: 2024-08-27-37-3
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5690
Age of specimen: 42 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing