Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994947 DEA: 112T3644 EFIS: 1121000108
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-56-0.3/3.0
Work Description: CONSTRUCT JPCP, HMA, RHMA-G, SIGNS, BARRIERS, LANDSCAPE, & ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM EL CAMINO REAL UNDERCROSSING TO 0.3 MILE WEST OF CARMEL VALLEY ROAD OVERCROSSING
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5860 El Camino Real #200, Carlsbad, CA 92008
Resident Engineer: Steve Mcmillan Structure Rep.: Unknown
DIME Sample ID: 2024-08-27-34
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/27/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/28/2024
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: Field Sample
From where was the sample collected: Source
Laboratory sample identification: 0903-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
DIME Test ID: 2024-08-27-34-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 09/03/2024
Date Tested: 08/30/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Save Material for HMA Gradation
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4017 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6057.9 g
|
|
Mass of HMA Sample prior to ignition
|
2040.9 g
|
|
Corrected Asphalt Binder Content
|
4.78 %
|
|
Mass Loss
|
106.5 g
|
|
Mass of aggregate remaining after ignition
|
1934.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.44 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-08-27-34-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/03/2024
Date Tested: 08/30/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2506.9 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8977.7 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.495
|
|
Theoretical maximum density at 25°C (77°F)
|
155.3 lb/ft^3
|
DIME Test ID: 2024-08-27-34-3
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 09/03/2024
Date Tested: 08/30/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
Is an aggregate correction factor used?
|
No
|
|
Cumulative percent passing the 2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
|
Cumulative percent passing the 3/4 in. sieve
|
99 %
|
|
Cumulative percent passing the 1/2 in. sieve
|
86 %
|
|
Cumulative percent passing the 3/8 in. sieve
|
71 %
|
|
Cumulative percent passing the #4 sieve
|
45 %
|
|
Cumulative percent passing the #8 sieve
|
33 %
|
|
Cumulative percent passing the #16 sieve
|
23 %
|
|
Cumulative percent passing the #30 sieve
|
16 %
|
|
Cumulative percent passing the #50 sieve
|
10 %
|
|
Cumulative percent passing the #100 sieve
|
7 %
|
|
Cumulative percent passing the #200 sieve
|
4.7 %
|