|
Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 033F0704 Cty SAC Rte 51 PM 2.0/3.5 Vendor # |
|
REPORT OF LABORATORY TESTING |
||||
|
Resident Engineer: |
John Ruzic |
Date Reported: |
09/23/2024 |
|
|
Address: |
TL Number: |
|
||
|
City: |
||||
|
Project Name: American River Bridge Rehabilitation |
||||
|
Prime Contractor: American River Constructors |
||||
|
Sample Taken Date: |
08/26/2024 |
Mix Design: |
1619190 |
|
|
Contractor: Unknown |
Location : |
|||
|
Structure unique identifier: |
||||
|
Structure name: |
||||
|
Location of Pour: |
||||
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 4.01 | 12.63 | 60599 | 4798.0 | 2 |
| 2 | 4.01 | 12.63 | 74196 | 5875.0 | 1 |
| 3 | 4.01 | 12.63 | 66553 | 5270 | 2 |
DIME Test ID: 2024-08-26-27-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 5310
Age of specimen: 28 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
| Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
|---|---|---|---|---|---|
| 1 | 3.99 | 12.5 | 59859 | 4787.0 | 1 |
| 2 | 4.01 | 12.63 | 57696 | 4568.0 | 1 |
| 3 | 4.01 | 12.63 | 58816 | 4657 | 1 |
DIME Test ID: 2024-08-26-27-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4670
Age of specimen: 8 days
Certified By: Spencer Adams
|
*Subject to final inspection by the Resident Engineer. |
|
TL- Report of Laboratory Testing