Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000022 DEA: 051Q4904 EFIS: 0523000037
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO,SB-166-R30.4/R35.0
Work Description: COLD PLANE AC PAVEMENT AND OVERLAY WITH RHMA-G.
Location Description: SANTA BARBARA AND SAN LUIS OBISPO COUNTIES ABOUT 20 MILES EAST OF SANTA MARIA FROM CUYAMA RIVER BRIDGE TO CUYAMA RIVER BRIDGE.
Contractor Name: GRIFFITH COMPANY
Contractor Address: Unknown
Resident Engineer: Philip Gaston Structure Rep.: Unknown
DIME Sample ID: 2024-08-26-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Santa Maria Field Laboratory
Sample Organization Contact: 8053191237
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/26/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2024
The quantity of what the sample constitutes: 750 Tons
A brief description of the sample: 1 box 1/2" RHMA G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith Edmonston
DIME Test ID: 2024-08-26-26-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/28/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D05 - San Luis Obispo District Laboratory
Organization Address: 50 Higuera Street,
Organization City: San Luis Obispo
Organization State: CA
Organization Zipcode: 93401
Organization Email: daniel.gingras@dot.ca.gov
Organization Phone: (805) 549-3141
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of HMA Sample prior to ignition
|
1629.7 g
|
|
Corrected Asphalt Binder Content
|
7.37 %
|
|
Mass Loss
|
126.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.39 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|