Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 1000165 DEA: 09392504 EFIS: 0923000029
QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-R17.2/25.8
Work Description: HOT MIX ASPHALT (TYPE A), SHOULDER BACKING, & STRIPING.
Location Description: INYO COUNTY ABOUT 9 MILES SOUTH OF OLANCHA FROM 0.8 MILE SOUTH OF SYKES ROAD TO 0.3 MILE NORTH OF HAIWEE CANYON ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 8999 Capacity Street, Arvin, CA 93203
Resident Engineer: Garret Rottner Structure Rep.: Unknown
DIME Sample ID: 2024-08-26-2
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/26/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/26/2024
The quantity of what the sample constitutes: 1 box
A brief description of the sample: 3/4” HMA
From where was the sample collected: Job Site
Laboratory sample identification: HMA 3
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Solari plant Granite Arvin
DIME Test ID: 2024-08-26-2-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/27/2024
Date Tested: 08/27/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-3
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of Samples
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water 1
|
7310.5 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2233.6 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
8664.8 grams
|
|
Temperature of Water
|
77.3 °F
|
|
Specific Gravity for Sample 1
|
2.54
|
|
Theoretical maximum density at 25°C (77°F)
|
158.1 lb/ft^3
|
DIME Test ID: 2024-08-26-2-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/27/2024
Date Tested: 08/27/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: HMA-3
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4245.2 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6398.8 g
|
|
Mass of HMA Sample prior to ignition
|
2153.6 g
|
|
Corrected Asphalt Binder Content
|
4.76 %
|
|
Mass Loss
|
116.2 g
|
|
Mass of aggregate remaining after ignition
|
2037.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.64 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|