Print Report | Back to Sample Detail

Sample Record for 2024-08-20-56

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994436 DEA: 11080284 EFIS: 1117000085 QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-98-32.1/32.5
Work Description: Place HMA, minor concrete, modify drainage, landscape and electrical.
Location Description: IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE
Contractor Name: Ral Investment Corporation
Contractor Address: 10065 Old Grove Rd Ste 200, San Diego, CA, 92131-1664
Resident Engineer: Daniel HERNANDEZ DUARTE Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-20-56
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 08/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2024
The quantity of what the sample constitutes: 5 bags
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Source
Laboratory sample identification: 5311-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: API Gateway

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-13-0057
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number: 1
Sublot number: 1
Aggregate Mix Number: 2

Test Results

Test 1 of 5

DIME Test ID: 2024-08-20-56-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 77 %
Cumulative percent passing the 1/2 in. sieve 4 %
Cumulative percent passing the 3/8 in. sieve 1 %
Cumulative percent passing the #4 sieve 1 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve 1 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve 1 %
Cumulative percent passing the #100 sieve 1 %
Cumulative percent passing the #200 sieve 0.5 %

Test 2 of 5

DIME Test ID: 2024-08-20-56-2
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 75 %
Cumulative percent passing the 3/8 in. sieve 15 %
Cumulative percent passing the #4 sieve 1 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve 1 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve 1 %
Cumulative percent passing the #100 sieve 1 %
Cumulative percent passing the #200 sieve 0.5 %

Test 3 of 5

DIME Test ID: 2024-08-20-56-3
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 90 %
Cumulative percent passing the #4 sieve 14 %
Cumulative percent passing the #8 sieve 1 %
Cumulative percent passing the #16 sieve no data0 %
Cumulative percent passing the #30 sieve no data0 %
Cumulative percent passing the #50 sieve no data0 %
Cumulative percent passing the #100 sieve no data0 %
Cumulative percent passing the #200 sieve 0.2 %

Test 4 of 5

DIME Test ID: 2024-08-20-56-4
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 100 %
Cumulative percent passing the #8 sieve 16 %
Cumulative percent passing the #16 sieve 1 %
Cumulative percent passing the #30 sieve 1 %
Cumulative percent passing the #50 sieve no data0 %
Cumulative percent passing the #100 sieve no data0 %
Cumulative percent passing the #200 sieve 0.2 %

Test 5 of 5

DIME Test ID: 2024-08-20-56-5
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 100 %
Cumulative percent passing the #8 sieve 93 %
Cumulative percent passing the #16 sieve 76 %
Cumulative percent passing the #30 sieve 57 %
Cumulative percent passing the #50 sieve 54 %
Cumulative percent passing the #100 sieve 16 %
Cumulative percent passing the #200 sieve 15.9 %