Print Report | Back to Sample Detail

Sample Record for 2024-08-20-55

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994436 DEA: 11080284 EFIS: 1117000085 QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-98-32.1/32.5
Work Description: Place HMA, minor concrete, modify drainage, landscape and electrical.
Location Description: IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE
Contractor Name: Ral Investment Corporation
Contractor Address: 10065 Old Grove Rd Ste 200, San Diego, CA, 92131-1664
Resident Engineer: Daniel HERNANDEZ DUARTE Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-20-55
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/20/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2024
The quantity of what the sample constitutes: 2 boxes
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Source
Laboratory sample identification: 5311-A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: API Gateway

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: 2
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-08-20-55-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/29/2024
Date Tested: 08/28/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: complies
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3964 g
Mass of the specimen and specimen basket assembly prior to ignition 5490.8 g
Mass of HMA Sample prior to ignition 1526.8 g
Corrected Asphalt Binder Content 4.46 %
Mass Loss 73.2 g
Mass of aggregate remaining after ignition 1453.6 g
Correction Factor (Percent by mass of HMA Specimen) 0.33 %
Moisture Content no data0 %
Temperature Compensation Factor no data0 %
Test Temperature 538 C