Print Report | Back to Sample Detail

Sample Record for 2024-08-21-60

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-21-60
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM6 - Ductile Iron Cast Samples
Sample Taken Date: 08/21/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/22/2024
The quantity of what the sample constitutes: 12
A brief description of the sample: Ductile Iron Casting
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: SDI

Material Information

Heat Number (s): B023 B074 C064 C064 H312 I012 I222 J192 J202
Part Number (s): ACS 31 6 AH SDI 19 6 AH SDI 12 6 PC BP SDI 19
Material Specification: A536
Grades: 80-55-06
Metal Foundry Manufacturer (Mill): Farrar Corporation
Prestressing Manufacturer: SDI

Test Results

Test 1 of 1

DIME Test ID: 2024-08-21-60-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 10/14/2024
Date Tested: 09/24/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 12
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
J2720.50.19635649131148898.5aauvinen
B0230.50.196356267110952910.6rmacias
I0120.50.19635616281069889.4aauvinen
C0640.50.19635635771112849.7aauvinen
I2220.4990.19556620651094059.8aauvinen
B0740.50.19635618581079548.9aauvinen
C0640.50.19635645881121097.7aauvinen
H3120.5010.19714605931015026.4aauvinen
J1920.50.19635618041085279.4aauvinen
K1530.50.19635626631086117.9aauvinen
K0830.50.19635646201125577aauvinen
J2020.50.19635630211091288.4aauvinen
UTM 67kip
Temperature 72 F