Print Report | Back to Sample Detail

Sample Record for 2024-08-23-28

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 1000165 DEA: 09392504 EFIS: 0923000029 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-R17.2/25.8
Work Description: HOT MIX ASPHALT (TYPE A), SHOULDER BACKING, & STRIPING.
Location Description: INYO COUNTY ABOUT 9 MILES SOUTH OF OLANCHA FROM 0.8 MILE SOUTH OF SYKES ROAD TO 0.3 MILE NORTH OF HAIWEE CANYON ROAD
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 8999 Capacity Street, Arvin, CA 93203
Resident Engineer: Garret Rottner Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-23-28
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/23/2024
The quantity of what the sample constitutes: 1 box 2 cores
A brief description of the sample: 3/4" HMA cores
From where was the sample collected: Job Site
Laboratory sample identification: PSU-2 CR-2A, 2B
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Solari plant Granite Arvin

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-08-23-28-1
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/26/2024
Date Tested: 08/26/2024
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: PSU-2 Cores
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 7.1 %
Percent Air Voids 2 6.8 %
Average Percent Air Voids 6.9 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-08-23-28-2AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)08/23/2024Not scheduledJoshua HubarttCT D09 - Bishop Field LaboratoryDerek Carrington