Print Report | Back to Sample Detail

Sample Record for 2024-08-15-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995482 DEA: 112T36U4 EFIS: 1122000243 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-5-37.4-52.6
Work Description: I-5 NCC SEGMENT 4C
Location Description: I-5 in San Diego County at Various Locations from Lomas Santa Fe Drive Undercrossing to 0.2 Mile North of Oceanside Undercrossing
Contractor Name: Flatiron-Skanska-Stacy and Witbeck Joint Venture
Contractor Address: 1770 La Costa Meadows Drive, San Marcos, CA 92078
Resident Engineer: Yong Pak Structure Rep.: Phong Le

Sample Information

DIME Sample ID: 2024-08-15-47
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 08/15/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/19/2024
The quantity of what the sample constitutes: 3 bags
A brief description of the sample: JMFR
From where was the sample collected: Supplier
Laboratory sample identification: 0609-JMFR
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Caroll Canyon

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-37-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 11

DIME Test ID: 2024-08-15-47-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 84 %
Cumulative percent passing the 3/8 in. sieve 68 %
Cumulative percent passing the #4 sieve 48 %
Cumulative percent passing the #8 sieve 37 %
Cumulative percent passing the #16 sieve 29 %
Cumulative percent passing the #30 sieve 21 %
Cumulative percent passing the #50 sieve 13 %
Cumulative percent passing the #100 sieve 8 %
Cumulative percent passing the #200 sieve 6 %

Test 2 of 11

DIME Test ID: 2024-08-15-47-2
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method 1 - Combined Fracture Determination
Aggregate Size and Fracture Type Coarse 2 Faced and Fine 1 Faced
Percentage of questionable, coarse, 2 faced particles tested no data0 %
Percentage of questionable, fine, 1 faced particles tested no data0 %
Percentage of fractured, coarse, 2 faced particles tested 99 %
Percentage of fractured, fine, 1 faced particles tested 100 %

Test 3 of 11

DIME Test ID: 2024-08-15-47-3
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Method B
Determination By Number
Dimensional ratio used 5:1
Weighted percentage of particles (by number) that were flat and elongated 0 %
Weighted percentage of particles (by number) that were not flat and elongated 0 %

Test 4 of 11

DIME Test ID: 2024-08-15-47-4
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Comples
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 65

Test 5 of 11

DIME Test ID: 2024-08-15-47-5
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk specific gravity 2.572
Bulk specific gravity (SSD Basis) 2.619
Apparent specific gravity 2.700
Absorption 1.8 %

Test 6 of 11

DIME Test ID: 2024-08-15-47-6
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Basis for relative density testing Bulk SSD
Specific Gravity 2.715
Absorption 1 %

Test 7 of 11

DIME Test ID: 2024-08-15-47-7
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Grading designation B
Mass of sample on No.12 sieve (after 500 revolutions) 4235 grams
Percent loss after 100 revolutions 4 %
Percent loss after 500 revolutions 15 %

Test 8 of 11

DIME Test ID: 2024-08-15-47-8
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What test method is performed? Method A
Bulk dry specific gravity 2.572
Average uncompacted voids 46.2 %

Test 9 of 11

DIME Test ID: 2024-08-15-47-9
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/23/2024
Date Tested: 08/20/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: RAP Rice Complies
Test Result Compliance: complies
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7475.6 grams
Mass of oven-dry sample in air for Sample 1 1529.9 grams
Mass of container filled with the sample and water for Sample 1 8398.7 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.521
Theoretical maximum density at 25°C (77°F) 156.9 lb/ft^3

Test 10 of 11

DIME Test ID: 2024-08-15-47-10
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: Complies
Test Result Compliance: complies
Additional Comments When Verified:
Is an aggregate correction factor used? No
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 100 %
Cumulative percent passing the 1/2 in. sieve 100 %
Cumulative percent passing the 3/8 in. sieve 94 %
Cumulative percent passing the #4 sieve 79 %
Cumulative percent passing the #8 sieve 64 %
Cumulative percent passing the #16 sieve 50 %
Cumulative percent passing the #30 sieve 36 %
Cumulative percent passing the #50 sieve 24 %
Cumulative percent passing the #100 sieve 16 %
Cumulative percent passing the #200 sieve 11.3 %

Test 11 of 11

DIME Test ID: 2024-08-15-47-11
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Verified Date: 08/23/2024
Date Tested: 08/21/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Plastic limit (PL) 1 %