| What temperature unit is used? | Celsius |
| Test procedure used? | Method A |
| Mass of the specimen basket assembly | 4038.7 g |
| Mass of the specimen and specimen basket assembly prior to ignition | 6092.9 g |
| Mass of HMA Sample prior to ignition | 2054.2 g |
| Corrected Asphalt Binder Content | 5.45 % |
| Mass Loss | 126 g |
| Mass of aggregate remaining after ignition | 1928.2 g |
| Correction Factor (Percent by mass of HMA Specimen) | 0.68 % |
| Moisture Content | no data0 % |
| Temperature Compensation Factor | no data0 % |
| Test Temperature | 538 C |
| Number of Samples | 1 |
| What is the unit of measurement for theoretical density? | US Units |
| Mass Determination | Air |
| Method Performed | Mechanical Agitation - Method A |
| Mass of container filled with water 1 | 7475.6 grams |
| Mass of oven-dry sample in air for Sample 1 | 2511 grams |
| Mass of container filled with the sample and water for Sample 1 | 8987.5 grams |
| Temperature of Water | 77 °F |
| Specific Gravity for Sample 1 | 2.513 |
| Theoretical maximum density at 25°C (77°F) | 156.4 lb/ft^3 |
| Is an aggregate correction factor used? | No |
| Cumulative percent passing the 2 in. sieve | 100 % |
| Cumulative percent passing the 1 1/2 in. sieve | 100 % |
| Cumulative percent passing the 1 in. sieve | 100 % |
| Cumulative percent passing the 3/4 in. sieve | 99 % |
| Cumulative percent passing the 1/2 in. sieve | 89 % |
| Cumulative percent passing the 3/8 in. sieve | 79 % |
| Cumulative percent passing the #4 sieve | 57 % |
| Cumulative percent passing the #8 sieve | 43 % |
| Cumulative percent passing the #16 sieve | 31 % |
| Cumulative percent passing the #30 sieve | 22 % |
| Cumulative percent passing the #50 sieve | 14 % |
| Cumulative percent passing the #100 sieve | 8 % |
| Cumulative percent passing the #200 sieve | 5.7 % |