Sample Record for 2024-07-24-79
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 214486 DEA: 080K1224 EFIS: 0815000244
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-15-R28.6/37.5
Work Description: REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location Description: SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
Contractor Name: SULLY - MILLER CONTRACTING COMPANY
Contractor Address: 135 S STATE COLLEGE BLVD. 400, BREA, CA 92821
Resident Engineer: Larry J Canuti Structure Rep.: Taghreed Al-khateeb
Sample Information
DIME Sample ID: 2024-07-24-79
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Los Angeles Field Office
Sample Organization Contact: (858) 285-5797
Type of Sample: Retest
Type of Material: SMTL TM7 - Epoxy Coated Dowels
Sample Taken Date: 07/24/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/25/2024
The quantity of what the sample constitutes: 14,616 linear ft
A brief description of the sample: Epoxy Coated Dowel Basket
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Pacific Highway Products
Material Information
Dowel Metal Heat Number: 4400031666, 4400029072, 4400029071, 4400029073, 4400029069,
Dowel Epoxy Batch Number: CH0954MK
Dowel Coating Specification: ASTM A934
Dowel Size: 1.5 in
Dowel Coating Color: Purple
Dowel Manufacturer: Nucor
Dowel Coater: Simcote
Release Number:
Quality Assurance Code: L140-073-24
Rebar Size (#):
Test Results
Test 1 of 2
DIME Test ID: 2024-07-24-79-2
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
First Bar Mean
|
11.12
|
|
Second Bar Mean
|
15.36
|
|
Lower spec. limit LSL
|
7 mils
|
|
Upper spec. limit USL
|
40 mils
|
|
Total mean value
|
13.24
|
|
Total number of values less than LSL
|
no data
|
|
Total number of values greater than USL
|
no data
|
Test 2 of 2
DIME Test ID: 2024-07-24-79-3
Test Method: ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Holiday)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Total Number of Holiday
|
no data0
|
|
Total Length
|
3
|
|
Holidays Per Linear Foot of Bar
|
no data0 holiday per ft
|
|
Holiday Test Pass/Fail
|
Pass
|
Tests Assigned to this Sample
| DIME Test ID | Test Method | Assigned Date | Test Date | Assigned By | Assigned Lab | Test Comments | Assigned To |
| 2024-07-24-79-1 | ASTM A884-19e20: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness) | 08/13/2024 | Not scheduled | Brian Murray | CT HQ - QASI Los Angeles Field Office | | |
112381