Print Report | Back to Sample Detail

Sample Record for 2024-08-07-73

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994872 DEA: 060X1604 EFIS: 0618000183 QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-58-R64.4/67.3
Work Description: HMA (TYPE A), RHMA-G, JPCP, CRCP & HIGH SPEED WEIGH-IN-MOTION SYSTEM.
Location Description: KERN COUNTY NEAR EDISON FROM 0.2 MILE WEST OF TEJON HIGHWAY OVERCROSSING TO CALIENTE CREEK BRIDGE
Contractor Name: GRIFFITH COMPANY
Contractor Address: 1128 Carrier Parkway Avenue, Bakersfield, CA 93308
Resident Engineer: Mandeep Chahal Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-08-07-73
TL Number from the TL Form: C754495
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 08/07/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/12/2024
The quantity of what the sample constitutes: 3 CAN
A brief description of the sample: PG 70-10 3/4" HMA Type A
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith STORAGE TANK

Material Information

Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number: 9001
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: San Joaquin Refinery - Bakersfield CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2024-08-07-73-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/15/2024
Date Tested: 08/14/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: ORG
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.148 kPa
Phase Angle (δ) (for the 10 cycles) 89.4 degree
Complex Modulus (G*) (for the 10 measurements) 1.230 kPa
Test Temperature (Specimen 1) 70.0 C
Dynamic Shear, G*/sin(δ) 1.23 kPa

Test 2 of 5

DIME Test ID: 2024-08-07-73-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.229 kPa
Phase Angle (δ) (for the 10 cycles) 88.7 degree
Complex Modulus (G*) (for the 10 measurements) 2.282 kPa
Test Temperature (Specimen 1) 70.0 C
Dynamic Shear, G*/sin(δ) 2.28 kPa

Test 3 of 5

DIME Test ID: 2024-08-07-73-3
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance:
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 72.367 kPa
Phase Angle (δ) (for the 10 cycles) 57.9 degree
Complex Modulus (G*) (for the 10 measurements) 7200.318 kPa
Test Temperature (Specimen 1) 34.0 C
(G*) x sin(δ)= 6100 kPa

Test 4 of 5

DIME Test ID: 2024-08-07-73-4
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCT
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) 150 cm
Ductility of sample 150 cm

Test 5 of 5

DIME Test ID: 2024-08-07-73-5
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/15/2024
Date Tested: 08/15/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV +3 C
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 42.620 kPa
Phase Angle (δ) (for the 10 cycles) 61.8 degree
Complex Modulus (G*) (for the 10 measurements) 4240.662 kPa
Test Temperature (Specimen 1) 37.0 C
(G*) x sin(δ)= 3737 kPa