Print Report | Back to Sample Detail

Sample Record for 2024-08-06-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994592 DEA: 081J7004 EFIS: 0818000097 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R59.3/R59.5
Work Description: HIGH SPEED WEIGH IN MOTION SYSTEM, JPCP,HMA, AND MODIFYING CMS SYSTEM.
Location Description: RIVERSIDE COUNTY IN COACHELLA FROM 0.4 MILE TO 0.6 MILE EAST OF DILLON ROAD UNDERCROSSING
Contractor Name: RE CHAFFEE CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Khoi Vu Structure Rep.: Hien Vu

Sample Information

DIME Sample ID: 2024-08-06-48
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/06/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/08/2024
The quantity of what the sample constitutes: 4 BOXES OF HMA, 2 QTS OF PG 58-22, 1 QT OF LAS
A brief description of the sample: 1/2" HMA A SP R25 .5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0377A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: GRANITE CONSTRUCTION DESERT HOT SPRINGS

Material Information

HMA Type: Type A HMA
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 3922
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 1

DIME Test ID: 2024-08-06-48-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/13/2024
Date Tested: 08/12/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 1605.7 g
Corrected Asphalt Binder Content 4.91 %
Mass Loss 85.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.29 %
Moisture Content no data0 %
Temperature Compensation Factor 0.13 %
Test Temperature 538 C