Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 44444 DEA: ASCP EFIS: ASCP
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for submitting Sample information for Asphalt Supplier Certification Program.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2024-07-23-106
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Verification
Type of Material: Asphalt Binder
Sample Taken Date: 07/23/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/23/2024
The quantity of what the sample constitutes: 1 of 2, split sample
A brief description of the sample: Tank 50K1
From where was the sample collected: Manufacturer
Laboratory sample identification: 240723-7010-01
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Coolidge, AZ
Performance Grade: PG 70-10
Modified: No
Lot number:
Sublot number:
Tank number: 50K1
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Western Emulsions Incorporated - Coolidge AZ
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2024-07-23-106-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/14/2024
Date Tested: 08/13/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
10.00 %
|
|
Stress Amplitude
|
0.387 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
83.5 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
3.847 kPa
|
|
Test Temperature (Specimen 1)
|
70.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
3.87 kPa
|
DIME Test ID: 2024-07-23-106-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/14/2024
Date Tested: 08/13/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: OG
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
12.00 %
|
|
Stress Amplitude
|
0.158 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
87.3 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
1.311 kPa
|
|
Test Temperature (Specimen 1)
|
70.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
1.31 kPa
|
DIME Test ID: 2024-07-23-106-3
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 08/14/2024
Date Tested: 08/14/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Test Gap
|
2 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
1.00 %
|
|
Stress Amplitude
|
50.528 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
44.7 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
5027.483 kPa
|
|
Test Temperature (Specimen 1)
|
34.0 C
|
|
(G*) x sin(δ)=
|
3536 kPa
|
DIME Test ID: 2024-07-23-106-4
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 08/14/2024
Date Tested: 08/14/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCT
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
150 cm
|
|
Ductility of sample
|
150 cm
|