Project ID: 994592 DEA: 081J7004 EFIS: 0818000097
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R59.3/R59.5
Work Description: HIGH SPEED WEIGH IN MOTION SYSTEM, JPCP,HMA, AND MODIFYING CMS SYSTEM.
Location Description: RIVERSIDE COUNTY IN COACHELLA FROM 0.4 MILE TO 0.6 MILE EAST OF DILLON ROAD UNDERCROSSING
Contractor Name: RE CHAFFEE CONSTRUCTION INC.
Contractor Address: Unknown
Resident Engineer: Khoi Vu Structure Rep.: Hien Vu
DIME Sample ID: 2024-08-01-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 08/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 08/05/2024
The quantity of what the sample constitutes: 4 BOXES OF HMA
A brief description of the sample: 1/2" HMA-A-SP R 25 0.5% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0364A-24
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Granite Construction-Desert Hot Springs
DIME Test ID: 2024-08-01-30-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/08/2024
Date Tested: 08/06/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
1606.1 g
|
Corrected Asphalt Binder Content
|
4.94 %
|
Mass Loss
|
86.3 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.25 %
|
Moisture Content
|
no data0 %
|
Temperature Compensation Factor
|
0.19 %
|
Test Temperature
|
538 C
|