Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994331 DEA: 11430254 EFIS: 1118000079
QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-52-5.1/9.0
Work Description: CONST AUX LANE, COMPACTION GROUTING, RHMA, LANDSCAPE, & ELECTRICAL.
Location Description: SAN DIEGO COUNTY IN SAN DIEGO FROM 0.4 MILE WEST OF CONVOY STREET OVERCROSSING TO 0.3 MILE EAST OF SANTO ROAD OVERCROSSING
Contractor Name: CSI/CJA A JOINT VENTURE
Contractor Address: 9685 VIA EXCLENCIA STREET #200, SAN DIEGO, CA 92126
Resident Engineer: karl Hartline Structure Rep.: Unknown
DIME Sample ID: 2024-07-30-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 518-8709
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/30/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/30/2024
The quantity of what the sample constitutes: 12 boxes
A brief description of the sample: HMA
From where was the sample collected: Source
Laboratory sample identification: 0802-PSU
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta
DIME Test ID: 2024-07-30-25-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/09/2024
Date Tested: 08/05/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.30 %Save sample for T30
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4006.9 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6041 g
|
|
Mass of HMA Sample prior to ignition
|
2034.1 g
|
|
Corrected Asphalt Binder Content
|
4.76 %
|
|
Mass Loss
|
108.7 g
|
|
Mass of aggregate remaining after ignition
|
1925.4 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.58 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|
DIME Test ID: 2024-07-30-25-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/09/2024
Date Tested: 08/01/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 2.510 Tested 2.498
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of tests
|
1
|
|
What is the unit of measurement for theoretical density?
|
US Units
|
|
Mass Determination
|
Air
|
|
Method Performed
|
Mechanical Agitation - Method A
|
|
Mass of container filled with water
|
7475.6 grams
|
|
Mass of oven-dry sample in air for Sample 1
|
2545.2 grams
|
|
Mass of container filled with the sample and water for Sample 1
|
9001.8 grams
|
|
Temperature of Water
|
77 °F
|
|
Specific Gravity for Sample 1
|
2.498
|
|
Theoretical maximum density at 25°C (77°F)
|
155.5 lb/ft^3
|
DIME Test ID: 2024-07-30-25-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/09/2024
Date Tested: 08/02/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.0% Tested Average of 3.9%
Test Result Compliance:
Additional Comments When Verified:
|
Percent Air Voids
|
3.8 %
|
|
Percent Air Voids 2
|
4 %
|
|
Percent Air Voids 3
|
4 %
|
|
Average Percent Air Voids
|
3.9 %
|
DIME Test ID: 2024-07-30-25-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/09/2024
Date Tested: 08/02/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target 4.% Tested Average of 3.9%
Test Result Compliance: complies
Additional Comments When Verified:
|
Bulk Specific Gravity
|
2.402
|
|
Bulk Specific Gravity 2
|
2.399
|
|
Bulk Specific Gravity 3
|
2.398
|
|
Average Bulk Specific Gravity
|
2.4
|
DIME Test ID: 2024-07-30-25-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 08/09/2024
Date Tested: 08/08/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Targets Wet > 70 psi & Dry > 100 psi
Test Result Compliance: complies
Additional Comments When Verified:
|
Unit system used?
|
SI Units
|
|
Average Dry Tensile Strength
|
134 psi
|
|
Average Wet Tensile Strength
|
116 psi
|
|
Tensile Strength Ratio
|
0.87
|
DIME Test ID: 2024-07-30-25-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 08/09/2024
Date Tested: 08/06/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: Complies Target < 12.7 mm Tested 1.77 mm
Test Result Compliance: complies
Additional Comments When Verified:
|
Specimen Preparation Method
|
no data
|
|
Test Temperature
|
113 F
|
|
Air Void Content for specimen A-1
|
no data
|
|
Air Void Content for specimen A-2
|
no data
|
|
Air Void Content for specimen B-1
|
no data
|
|
Air Void Content for specimen B-2
|
no data
|
|
Stripping Inflection Point (Wheel A)
|
>10000
|
|
Stripping Inflection Point (Wheel B)
|
>10000
|
|
Maximum impression at 5000 passes (left wheel)
|
1.74 mm
|
|
Maximum impression at 5000 passes (right wheel)
|
1.33 mm
|
|
Average impression at 5000 passes (left/right avg)
|
1.54 mm
|
|
Maximum impression at 10000 passes (left wheel)
|
2.06 mm
|
|
Maximum impression at 10000 passes (right wheel)
|
1.48 mm
|
|
Average impression at 10000 passes (left/right avg)
|
1.77 mm
|
|
Average impression at 15000 passes (left/right avg)
|
no data
|
|
Average impression at 20000 passes (left/right avg)
|
no data
|
|
Average impression at 25000 passes (left/right avg)
|
no data
|
DIME Test ID: 2024-07-30-25-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/09/2024
Date Tested: 08/01/2024
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 4050 Taylor Street,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92110
Organization Email: benjamin.haney@dot.ca.gov
Organization Phone: (858) 688-1595
General Comments for this Test: COMPLIES - 3 RAP burns, Save 1 sample for T30
Test Result Compliance: complies
Additional Comments When Verified:
|
What temperature unit is used?
|
Celsius
|
|
Test procedure used?
|
Method A
|
|
Mass of the specimen basket assembly
|
4015.7 g
|
|
Mass of the specimen and specimen basket assembly prior to ignition
|
5665.9 g
|
|
Mass of HMA Sample prior to ignition
|
1650.2 g
|
|
Corrected Asphalt Binder Content
|
7.16 %
|
|
Mass Loss
|
118.2 g
|
|
Mass of aggregate remaining after ignition
|
1532 g
|
|
Correction Factor (Percent by mass of HMA Specimen)
|
no data0 %
|
|
Moisture Content
|
no data0 %
|
|
Temperature Compensation Factor
|
no data0 %
|
|
Test Temperature
|
538 C
|