Print Report | Back to Sample Detail

Sample Record for 2024-07-01-89

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995054 DEA: 024H0204 EFIS: 0218000069 QA Service Level: 1
DIST-CO-RTE-PM: 02-TEH-36-20.0/39.7
Work Description: PLACE RHMA AND HMA, CORRECT SEGMENTS, AND REPLACE AC SURFACING.
Location Description: TEHAMA COUNTY NEAR RED BLUFF FROM 0.8 MILE EAST OF SALT CREEK BRIDGE TO BAKER ROAD
Contractor Name: TULLIS, INC.
Contractor Address: 16951 Clear Creek Road, Redding, CA 96049
Resident Engineer: Shoukie Alawar Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-07-01-89
TL Number from the TL Form: 853408
Sample Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Sample Organization Contact: (530) 225-3194
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/01/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2024
The quantity of what the sample constitutes: Production Start-Up Evaluation
A brief description of the sample: 16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR) virgin PG 64-16 from Valero – Benicia
From where was the sample collected: Manufacturer
Laboratory sample identification: D79614
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tullis Inc. - Northstate Asphalt (Redding CA)

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number:
Binder content (%):
Virgin binder PG:
Design binder PG:
Binder Supplier:
RAP content (%):
WMA Additives:
Antistrip type:

Test Results

Test 1 of 5

DIME Test ID: 2024-07-01-89-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 10/09/2024
Date Tested: 10/02/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pb=7.81
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3027.9 g
Mass of the specimen and specimen basket assembly prior to ignition 4589.6 g
Mass of HMA Sample prior to ignition 1561.7 g
Corrected Asphalt Binder Content 7.82 %
Mass Loss 132.7 g
Mass of aggregate remaining after ignition 1429 g
Correction Factor (Percent by mass of HMA Specimen) 0.49 %
Moisture Content no data0 %
Temperature Compensation Factor 0.19 %
Test Temperature 538 C

Test 2 of 5

DIME Test ID: 2024-07-01-89-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 07/08/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmm=2.433
Test Result Compliance:
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7333 grams
Mass of oven-dry sample in air for Sample 1 1570.3 grams
Mass of container filled with the sample and water for Sample 1 8257.9 grams
Temperature of Water 24 °F
Specific Gravity for Sample 1 2.433
Theoretical maximum density at 25°C (77°F) 2425.9 kg/m^3

Test 3 of 5

DIME Test ID: 2024-07-01-89-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 09/09/2024
Date Tested: 07/12/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Gmb=2.334
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.334
Bulk Specific Gravity 2 2.33
Bulk Specific Gravity 3 2.337
Average Bulk Specific Gravity 2.334

Test 4 of 5

DIME Test ID: 2024-07-01-89-4
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 09/09/2024
Date Tested: 07/12/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: Pa=4.1
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 4.1 %
Percent Air Voids 2 4.2 %
Percent Air Voids 3 3.9 %
Average Percent Air Voids 4.1 %

Test 5 of 5

DIME Test ID: 2024-07-01-89-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 09/09/2024
Date Tested: 09/09/2024
Submitted By Organization: CT D02 - Redding Northern Regional Laboratory
Organization Address: 1657 Riverside Drive,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: ward.jenkins@dot.ca.gov
Organization Phone: 530-225-3194
General Comments for this Test: S1=132 psi, S2=127 psi, TSR=97%
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 132 psi
Average Wet Tensile Strength 127 psi
Tensile Strength Ratio 0.96

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-07-01-89-6CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt07/24/2024Not scheduledColt SweenyCT D02 - Redding Northern Regional Laboratory