Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994889 DEA: 051M7304 EFIS: 0520000055
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-17-3.2/11.3
Work Description: HIGH FRICTION SURFACE TREATMENT, COLD PLANE AND PLACE HMA.
Location Description: SANTA CRUZ COUNTY IN AND NEAR SCOTT VALLEY FROM SOUTH OF MT HERMON ROAD TO 0.6 MILE NORTH OF GLENWOOD DRIVE
Contractor Name: GRANITE ROCK COMPANY
Contractor Address: 350 Technology Drive, Watsonville, CA 95076
Resident Engineer: Farshad Keshavarzi Structure Rep.: Unknown
DIME Sample ID: 2024-07-18-49
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: High Friction Surface Treatment
Sample Taken Date: 07/18/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/19/2024
The quantity of what the sample constitutes: 34 Totes
A brief description of the sample: 1 gallon can / HFST RESIN
From where was the sample collected: Source
Laboratory sample identification: 000096KBP
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2024-07-18-49-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 08/27/2024
Date Tested: 08/27/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: ASTM C881 (Gel time): 27 mins.
ASTM D1640 (Cure rate): 1.25 hrs
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2024-07-18-49-2
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 08/27/2024
Date Tested: 07/25/2024
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joe.harline@dot.ca.gov
Organization Phone: (916) 206-4373
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
|
Number of specimens tested
|
6
|
|
Conditioning procedure
|
18/25/50+5/70
|
|
Speed of testing
|
0.45 in/min
|
|
Sample 1 Width
|
0.137 in
|
|
Sample 1 Ultimate strength
|
3789 psi
|
|
Sample 1 Thickness
|
0.491 in
|
|
Sample 1 Area
|
0.0673 in^2
|
|
Sample 1 Ultimate Strength Actual
|
255 lbs
|
|
Sample 1 percent elongation
|
40 %
|
|
Sample 1 Time
|
no data0 MM:SS
|
|
Sample 2 Width
|
0.138 in
|
|
Sample 2 Thickness
|
0.487 in
|
|
Sample 2 Area
|
0.0672 in^2
|
|
Sample 2 Ultimate strength
|
3943.5 psi
|
|
Sample 2 Ultimate Strength Actual
|
265 lbs
|
|
Sample 2 percent elongation
|
43 %
|
|
Sample 2 Time
|
no data0 MM:SS
|
|
Sample 3 Width
|
0.15 in
|
|
Sample 3 Thickness
|
0.487 in
|
|
Sample 3 Area
|
0.0731 in^2
|
|
Sample 3 Ultimate strength
|
3994.5 psi
|
|
Sample 3 Ultimate Strength Actual
|
292 lbs
|
|
Sample 3 percent elongation
|
60 %
|
|
Sample 3 Time
|
no data0 MM:SS
|
|
Sample 4 Width
|
0.139 in
|
|
Sample 4 Thickness
|
0.491 in
|
|
Sample 4 Area
|
0.0682 in^2
|
|
Sample 4 Ultimate strength
|
3944.3 psi
|
|
Sample 4 Ultimate Strength Actual
|
269 lbs
|
|
Sample 4 percent elongation
|
47 %
|
|
Sample 4 Time
|
no data0 MM:SS
|
|
Sample 5 Width
|
0.147 in
|
|
Sample 5 Thickness
|
0.485 in
|
|
Sample 5 Area
|
0.0713 in^2
|
|
Sample 5 Ultimate strength
|
4039.3 psi
|
|
Sample 5 Ultimate Strength Actual
|
288 lbs
|
|
Sample 5 percent elongation
|
60 %
|
|
Sample 5 Time
|
no data0 MM:SS
|
|
Sample 6 Width
|
0.146 in
|
|
Sample 6 Thickness
|
0.492 in
|
|
Sample 6 Area
|
0.0718 in^2
|
|
Sample 6 Ultimate strength
|
4011.1 psi
|
|
Sample 6 Ultimate Strength Actual
|
288 lbs
|
|
Sample 6 percent elongation
|
52 %
|
|
Sample 6 Time
|
no data0 MM:SS
|
|
Ultimate Strength Average
|
3954 psi
|
|
Percent Elongation Average
|
50 %
|