Print Report | Back to Sample Detail

Sample Record for 2024-07-12-71

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995031 DEA: 023H82U4 EFIS: 0223000011 QA Service Level: 1
DIST-CO-RTE-PM: 02-LAS-44-0.0/37.2
Work Description: REPLACE AC SURFACING, PLACE RHMA, HMA, THERMOPLASTIC TRAFFIC STRIPE.
Location Description: LASSEN COUNTY ABOUT 9 MILES EAST OF OLD STATION FROM SHASTA COUNTY LINE TO ROUTE 36
Contractor Name: HAT CREEK CONSTRUCTION & MATERIALS, INC.
Contractor Address: 24339 Hwy 89 N, Burney, CA 96013
Resident Engineer: Edward Worden Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-07-12-71
TL Number from the TL Form: C848918
Sample Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Sample Organization Contact: (916) 227-7302
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 07/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/19/2024
The quantity of what the sample constitutes: 2 cans of RUBBERt Binder
A brief description of the sample: RUBBER
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Hat Creek Construction

Material Information

Asphalt modifier supplier: ALBINA KLAMATH
Performance Grade: PG 58-22
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:

Test Results

Test 1 of 3

DIME Test ID: 2024-07-12-71-1
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 07/25/2024
Date Tested: 07/24/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: CONE PEN
Test Result Compliance: complies
Additional Comments When Verified:
Determination Unworked Penetration
Unworked Penetration 39 0.1 mm

Test 2 of 3

DIME Test ID: 2024-07-12-71-2
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 07/25/2024
Date Tested: 07/24/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: SOFTENING POINT
Test Result Compliance: complies
Additional Comments When Verified:
ASTM Thermometer used? C
Softening Point Sample 1 66 C
Softening Point Sample 2 66 C
Bath Liquid freshly boiled distilled water
Minutes Reaction no data

Test 3 of 3

DIME Test ID: 2024-07-12-71-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 07/25/2024
Date Tested: 07/24/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RESILIENCE
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 25 C
Ball Penetration (P1) no data0 mm
Final Dial reading (F1) 58 mm
Ball Penetration (P2) no data0 mm
Final Dial reading (F2) 61 mm
Ball Penetration (P3) no data0 mm
Final Dial reading (F3) 59 mm
Resilience 1 42 %
Resilience 2 39 %
Resilience 3 41 %
Average Resilience 41 %
Minutes Reaction no data