Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995089 DEA: 010M8104 EFIS: 0123000072
QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-36-7/42
Work Description:
Location Description:
Contractor Name: Pacific Coast Drilling Co., Inc.
Contractor Address: 364 Bellevue Ave., Santa Rosa 95407
Resident Engineer: Cody Long Structure Rep.: George Moore
DIME Sample ID: 2024-07-17-42
TL Number from the TL Form: 971768
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 07/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2024
The quantity of what the sample constitutes: 1 can binder
A brief description of the sample: 1 can PG 58-22 binder
From where was the sample collected: Source
Laboratory sample identification: 24-122
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser B
Performance Grade: PG 58-22
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:
DIME Test ID: 2024-07-17-42-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/29/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Original
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
Original binder
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
12.00 %
|
|
Stress Amplitude
|
0.172 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
85.7 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
1.424 kPa
|
|
Test Temperature (Specimen 1)
|
58.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
1.43 kPa
|
DIME Test ID: 2024-07-17-42-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/29/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
RTFO residue
|
|
Test Gap
|
1 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
10.00 %
|
|
Stress Amplitude
|
0.417 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
80.5 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
4.145 kPa
|
|
Test Temperature (Specimen 1)
|
58.0 C
|
|
Dynamic Shear, G*/sin(δ)
|
4.20 kPa
|
DIME Test ID: 2024-07-17-42-3
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
|
Phase
|
PAV residue
|
|
Test Plate Diameter
|
8 mm
|
|
Test Gap
|
2 mm
|
|
Test Frequency
|
10.0 rad/s
|
|
Strain Amplitude
|
1.00 %
|
|
Stress Amplitude
|
37.843 kPa
|
|
Phase Angle (δ) (for the 10 cycles)
|
48.7 degree
|
|
Complex Modulus (G*) (for the 10 measurements)
|
3765.258 kPa
|
|
Test Temperature (Specimen 1)
|
22.0 C
|
|
(G*) x sin(δ)=
|
2829 kPa
|
DIME Test ID: 2024-07-17-42-4
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 07/31/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCT
Test Result Compliance: complies
Additional Comments When Verified:
|
Is a normal test obtainable?
|
Yes
|
|
Number of replicates tested
|
One
|
|
Ductility of test #1 (D1)
|
150 cm
|
|
Ductility of sample
|
150 cm
|