Print Report | Back to Sample Detail

Sample Record for 2024-07-17-42

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995089 DEA: 010M8104 EFIS: 0123000072 QA Service Level: 1
DIST-CO-RTE-PM: 01-HUM-36-7/42
Work Description:
Location Description:
Contractor Name: Pacific Coast Drilling Co., Inc.
Contractor Address: 364 Bellevue Ave., Santa Rosa 95407
Resident Engineer: Cody Long Structure Rep.: George Moore

Sample Information

DIME Sample ID: 2024-07-17-42
TL Number from the TL Form: 971768
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Acceptance
Type of Material: Asphalt Binder
Sample Taken Date: 07/17/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/17/2024
The quantity of what the sample constitutes: 1 can binder
A brief description of the sample: 1 can PG 58-22 binder
From where was the sample collected: Source
Laboratory sample identification: 24-122
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser B

Material Information

Performance Grade: PG 58-22
Modified: No
Lot number:
Sublot number:
Tank number:
Time of sample:
HMA Supplier:
Certified Asphalt Supplier: Valero Marketing & Supply - Benicia CA
Multigrade: No
Multigrade Type:
Asphalt Binder Mix Number:

Test Results

Test 1 of 4

DIME Test ID: 2024-07-17-42-1
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/29/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: Original
Test Result Compliance: complies
Additional Comments When Verified:
Phase Original binder
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 12.00 %
Stress Amplitude 0.172 kPa
Phase Angle (δ) (for the 10 cycles) 85.7 degree
Complex Modulus (G*) (for the 10 measurements) 1.424 kPa
Test Temperature (Specimen 1) 58.0 C
Dynamic Shear, G*/sin(δ) 1.43 kPa

Test 2 of 4

DIME Test ID: 2024-07-17-42-2
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/29/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: RTFO
Test Result Compliance: complies
Additional Comments When Verified:
Phase RTFO residue
Test Gap 1 mm
Test Frequency 10.0 rad/s
Strain Amplitude 10.00 %
Stress Amplitude 0.417 kPa
Phase Angle (δ) (for the 10 cycles) 80.5 degree
Complex Modulus (G*) (for the 10 measurements) 4.145 kPa
Test Temperature (Specimen 1) 58.0 C
Dynamic Shear, G*/sin(δ) 4.20 kPa

Test 3 of 4

DIME Test ID: 2024-07-17-42-3
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Verified Date: 07/31/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: PAV
Test Result Compliance: complies
Additional Comments When Verified:
Phase PAV residue
Test Plate Diameter 8 mm
Test Gap 2 mm
Test Frequency 10.0 rad/s
Strain Amplitude 1.00 %
Stress Amplitude 37.843 kPa
Phase Angle (δ) (for the 10 cycles) 48.7 degree
Complex Modulus (G*) (for the 10 measurements) 3765.258 kPa
Test Temperature (Specimen 1) 22.0 C
(G*) x sin(δ)= 2829 kPa

Test 4 of 4

DIME Test ID: 2024-07-17-42-4
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Verified Date: 07/31/2024
Date Tested: 07/30/2024
Submitted By Organization: CT HQ - Sacramento Asphalt Binder Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: guadalupe.magana@dot.ca.gov
Organization Phone: (530) 713-6823
General Comments for this Test: DUCT
Test Result Compliance: complies
Additional Comments When Verified:
Is a normal test obtainable? Yes
Number of replicates tested One
Ductility of test #1 (D1) 150 cm
Ductility of sample 150 cm