Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 995059 DEA: 081G6404 EFIS: 0816000046
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-395-R4.0/49.0
Work Description: REPLACE ASPHALT CONCRETE SURFACING, COLD PLANE AC PVMT AND RHMA.
Location Description: SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM ROUTE 15/395 SEPARATION TO 3.1 MILES NORTH OF ROUTE 58/395 SEPARATION
Contractor Name: SULLY-MILLER CONTRACTING COMPANY
Contractor Address: 135 S State College Blvd, Brea, Ca 92821
Resident Engineer: Shaun Loza Structure Rep.: Unknown
DIME Sample ID: 2024-06-26-102
TL Number from the TL Form: 1069-1A
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/26/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2024
The quantity of what the sample constitutes: 3
A brief description of the sample: Concrete Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 1069-1A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Not Provided
The concrete mix design number: SC590B39
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: NOT PROVIDED
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: CMS PM 17.40
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2024-06-26-102-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C1231 - Unbonded Elastomeric Pad Cap Cured in accordance with ASTM C511
Verified Date: 08/26/2024
Date Tested: 07/24/2024
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
|
Unit system used?
|
US Units
|
|
Number of specimens
|
3
|
|
Test performed
|
With no density determined
|
|
Cross sectional area of cylinder 1
|
12.63 in^2
|
|
Cross sectional area of cylinder 2
|
12.76 in^2
|
|
Cross sectional area of cylinder 3
|
12.69 in^2
|
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
|
Compressive strength (to nearest 10 psi)
|
4700 psi
|
|
Average diameter of cylinder 1
|
4.01 in
|
|
Average diameter of cylinder 2
|
4.03 in
|
|
Compressive strength of cylinder 1
|
4737.9 psi
|
|
Compressive strength of cylinder 2
|
4730.4 psi
|
|
Average diameter of cylinder 3
|
4.02 in
|
|
Compressive strength of cylinder 3
|
4632 psi
|
|
Maximum load on cylinder 1
|
59840 lb
|
|
Maximum load on cylinder 2
|
60360 lb
|
|
Maximum load on cylinder 3
|
58780 lb
|
|
Type of fracture pattern of cylinder 1
|
1
|
|
Type of fracture pattern of cylinder 2
|
1
|
|
Type of fracture pattern of cylinder 3
|
1
|
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
|
Correction factor for cylinder 1
|
1
|
|
Correction factor for cylinder 2
|
1
|
|
Correction factor for cylinder 3
|
1
|
|
Age of specimen
|
28 days
|