Print Report | Back to Sample Detail

Sample Record for 2024-06-03-111

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 995085 DEA: 07322904 EFIS: 0716000059 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-27-0.0/18.6
Work Description: REMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location Description: LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
Contractor Name: C. A. RASMUSSEN, INC.
Contractor Address: 28548 Livingston Ave, Valencia, CA 91355
Resident Engineer: Ravin Maru Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2024-06-03-111
TL Number from the TL Form:
Sample Submitted By Organization: Alta Vista Solutions - Whittier
Sample Organization Contact: (510) 542-9827
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/03/2024
Date that the sample was received by the laboratory/organization performing the testing: 06/04/2024
The quantity of what the sample constitutes: 10 CY
A brief description of the sample: 6 x 12 LCB Cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 24-1312
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: N/A

Material Information

The concrete mix design number: 12622-LCB-1
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 15
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2024-06-03-111-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/16/2024
Date Tested: 06/10/2024
Submitted By Organization: Alta Vista Solutions - Whittier
Organization Address: 12409 Slauson Avenue, Suite I,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90606
Organization Email: nicholas.hoffmann@oneatlas.com
Organization Phone: (510) 542-9827
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 5.95 in
Average diameter of cylinder 2 5.95 in
Cross sectional area of cylinder 1 27.81 in^2
Cross sectional area of cylinder 2 27.81 in^2
Compressive strength (to nearest 10 psi) 3480 psi
Maximum load on cylinder 1 94994 lb
Maximum load on cylinder 2 98497 lb
Compressive strength of cylinder 1 3415.8 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 3541.8 psi
Type of fracture pattern of cylinder 2 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days
Age of specimen in hours no data0 hours