Print Report | Back to Sample Detail

Sample Record for 2024-07-16-12

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215456 DEA: 07293604 EFIS: 0713000238 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-405-14.3/15.8
Work Description: CONSTRUCT AUXILIARY LANE AND WIDEN ON AND OFF RAMPS.
Location Description: LOS ANGELES COUNTY IN TORRANCE BETWEEN WESTERN AVENUE UNDERCROSSING AND WEST 182ND STREET
Contractor Name: ORTIZ ENTERPRISES, INC.
Contractor Address: 6 CUSHING SUITE 200, IRVINE CA 92618
Resident Engineer: Samuel Gallardo Structure Rep.: James Holloway

Sample Information

DIME Sample ID: 2024-07-16-12
TL Number from the TL Form: C006809
Sample Submitted By Organization: CT D07 - Plant Services
Sample Organization Contact: 562-345-3126
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 07/16/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/16/2024
The quantity of what the sample constitutes: 80 CY
A brief description of the sample: 1 x 4 PCC Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification: 030A
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex Ready Mix Concrete-Inglewood

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-36-0106
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: 4478B
A detailed description of where the material sample was collected: Plant Stockpile
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1 inch
The concrete mix design number: 1505437
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2024-07-16-12-1
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 08/09/2024
Date Tested: 07/16/2024
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
What type of gradation is being tested? 1 in. x No. 4 - Coarse Aggregate
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 93 %
Cumulative percent passing the 3/4 in. sieve 16 %
Cumulative percent passing the 1/2 in. sieve 26 %
Cumulative percent passing the 3/8 in. sieve 6 %
Cumulative percent passing the #4 sieve 2 %
Cumulative percent passing the #8 sieve no data0 %