Print Report | Back to Sample Detail

Sample Record for 2024-07-12-48

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994820 DEA: 060V1104 EFIS: 0616000208 QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE,KIN-5,41,198-Var
Work Description: STRATFORD KINGS RIVER BRIDGE REPLACEMENT.
Location Description: FRESNO AND KINGS COUNTIES AT VARIOUS LOCATIONS
Contractor Name: M.C.M. Construction, INC. (Richard McCall)
Contractor Address: 6413 32nd Street, North Highlands, Ca 95660
Resident Engineer: Din Dadawalla Structure Rep.: Martin Garcia

Sample Information

DIME Sample ID: 2024-07-12-48
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 341-3953
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/12/2024
Date that the sample was received by the laboratory/organization performing the testing: 07/15/2024
The quantity of what the sample constitutes: 9- 4X8 Cylinders
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 45-0110
Structure name:
The fabricator/manufacturer/facility name: MCM Construction

Material Information

The concrete mix design number: ND10531
The truck number from where the sample was collected: 1
The batch plant ticket number from where the sample was collected: 117195112
Concrete batch plant: Viking Ready Mix
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete from wheelbarrow
Where the material sample would have been placed if not sampled: Barrier End Block
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2024-07-12-48-6
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/30/2024
Date Tested: 07/30/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 3990 psi
Maximum load on cylinder 1 50500 lb
Maximum load on cylinder 2 51060 lb
Maximum load on cylinder 3 48940 lb
Compressive strength of cylinder 1 4017.5 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 4062.1 psi
Compressive strength of cylinder 3 3893.4 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 18 days
Age of specimen in hours no data0 hours

Test 2 of 2

DIME Test ID: 2024-07-12-48-7
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 08/09/2024
Date Tested: 08/09/2024
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 1352 W. Olive Ave,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93728
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 4370 psi
Maximum load on cylinder 1 54980 lb
Maximum load on cylinder 2 53770 lb
Maximum load on cylinder 3 55890 lb
Compressive strength of cylinder 1 4373.9 psi
Type of fracture pattern of cylinder 1 2
Compressive strength of cylinder 2 4277.6 psi
Compressive strength of cylinder 3 4446.3 psi
Type of fracture pattern of cylinder 2 2
Type of fracture pattern of cylinder 3 2
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours no data0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2024-07-12-48-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders07/15/2024Not scheduledFares ThwabahCT D06 - Millbrook Field Laboratory
2024-07-12-48-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders07/15/2024Not scheduledFares ThwabahCT D06 - Millbrook Field Laboratory
2024-07-12-48-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders07/15/2024Not scheduledFares ThwabahCT D06 - Millbrook Field Laboratory
2024-07-12-48-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders07/15/2024Not scheduledFares ThwabahCT D06 - Millbrook Field Laboratory
2024-07-12-48-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders07/15/2024Not scheduledFares ThwabahCT D06 - Millbrook Field Laboratory